D 2023

Using thermography for detecting mould growth

PLACHÝ, Jan; Pavlína CHARVÁTOVÁ and Tomáš NAVARA

Basic information

Original name

Using thermography for detecting mould growth

Name in Czech

Využití termografie pro diagnostiku vzniku plísní

Authors

Edition

Spojené státy americké, AIP Conference Proceedings, Volume 2928, issue 1: 7th World Multidisciplinary Civil Engineering-Architecture-Urban Planning Symposium, WMCAUS 2022, p. nestránkováno, 7 pp. 2023

Publisher

American Institute of Physics Inc.

Other information

Language

English

Type of outcome

Proceedings paper

Field of Study

20100 2.1 Civil engineering

Country of publisher

United States of America

Confidentiality degree

is not subject to a state or trade secret

Publication form

electronic version available online

References:

Marked to be transferred to RIV

Yes

RIV identification code

RIV/75081431:_____/23:00002782

Organization unit

Institute of Technology and Business in České Budějovice

ISSN

EID Scopus

Keywords (in Czech)

vytápění; větrání a klimatizace; termografie; termokamera

Keywords in English

Heating; ventilation; and air-conditioning; Thermography; Cameras

Tags

Changed: 18/2/2025 10:31, Ing. Barbora Langšádlová

Abstract

In the original language

The paper deals with the issue of mould formation in a prefabricated panel building. It is a panel building from the mid-20th century with the External Thermal Insulation composite system ETICS applied. To identify the cause of mould formation, diagnostics of the flat was performed with the aim to determine the composition of the envelope. The diagnostics was performed using a cut probe and thermographic testing. Extensive thermal bridges were detected using an IR camera. The identified cause of mould formation was insufficient insulation of the object and improper use of the apartment on the side of the tenants.

In Czech

Příspěvek se zabývá problematikou vzniku plísní v panelovém dome. Jedná se o panelový dům z poloviny minulého století, na kterém byl proveden kontaktní zateplovací system ETICS. Pro zjištění příčky vzniku plísně byla provedena diagnostika bytu. Cílem diagnostiky bylo zjistit skladbu obvodového pláště. Diagnostika byla provedena pomocí sekaných sond a termografického zkoušení. Pomocí IR kamery byly zjištěny rozsáhlé tepelné mosty. Příčinou vzniku plísní bylo nejen nedostatečné zateplení objektu a i špatné užívání bytu nájemníky.

Files attached

080005_1_5.0172016_compressed.pdf
Request the author's version of the file