D 2024

THE PROCESSING OF EXPERIMENTAL DATA FROM THE PHYSICAL MODEL OF A FDU REFINING UNIT

KOLÍNSKÝ, Jan; Tomáš PRÁŠIL; Ladislav SOCHA; Karel GRYC; Jana SVIŽELOVÁ et al.

Basic information

Original name

THE PROCESSING OF EXPERIMENTAL DATA FROM THE PHYSICAL MODEL OF A FDU REFINING UNIT

Authors

KOLÍNSKÝ, Jan; Tomáš PRÁŠIL; Ladislav SOCHA; Karel GRYC; Jana SVIŽELOVÁ; Martin DVOŘÁK and Petr NUSKA

Edition

OSTRAVA, CZECH REPUBLIC, METAL 2023 Conference Proceedings, p. 101-107, 717 pp. 2024

Publisher

TANGER LTD

Other information

Language

English

Type of outcome

Proceedings paper

Field of Study

20500 2.5 Materials engineering

Country of publisher

Czech Republic

Confidentiality degree

is not subject to a state or trade secret

Publication form

electronic version available online

References:

Marked to be transferred to RIV

Yes

RIV identification code

RIV/75081431:_____/24:00002834

Organization unit

Institute of Technology and Business in České Budějovice

ISSN

Keywords in English

Physical modelling; aluminium; degassing; experimental data; parameterization

Tags

Links

TH04010449, research and development project.
Changed: 9/4/2025 14:38, Ing. Barbora Langšádlová

Abstract

In the original language

The present paper describes a method for processing experimental data obtained on a physical model of a refining unit, the Foundry Degassing Unit (FDU). For different refining gas flow rates and rotor rotation speeds of the FDU, the concentration of oxygen removed was measured depending on time. A large number of experiments were carried out with different rotor types and under different conditions. After examining the character of the data obtained, a method was proposed to evaluate the performance of different rotor types in degassing at a given gas flow rate at different rotor speeds. This method is based on interpolating several degassing curves in such a way that the resulting characteristic can be expressed by a single parameter. This final parameter then allows the degassing efficiency (refining capacity) to be quantified. In this unique way, the degassing efficiency of different rotor types can then be objectively compared. Furthermore, the parameter thus obtained can be used to determine the expected time at which the desired decrease in the concentration of undesirable gas in the bath will occur. Attention is also paid to the possible deviation that occurs when a large amount of experimental data is reduced to a single parameter by the described approximation.

Files attached

THE_PROCESSING_OF_EXPERIMENTAL_DATA_FROM_THE_PHYSICAL_MODEL_OF_A_FDU_REFINING_UNIT.pdf
Request the author's version of the file