@inproceedings{65562, author = {Juhásová Šenitková, Ingrid and Kraus, Michal}, address = {Spojené státy americké}, booktitle = {6th World Multidisciplinary Civil Engineering-Architecture-Urban Planning Symposium (WMCAUS 2021)}, edition = {1}, editor = {Yilmaz I., Marschalko M., Drusa M.}, keywords = {Indoor Air Quality; office buildings; VOC; indoor environment; Sick Building Syndrome}, howpublished = {elektronická verze "online"}, language = {eng}, location = {Spojené státy americké}, isbn = {978-0-7354-4266-5}, pages = {nestránkováno}, publisher = {American Institute of Physics Inc.}, title = {Case study of VOC emissions in Czech office buildings}, url = {https://aip.scitation.org/doi/10.1063/5.0105178}, year = {2021} }
TY - JOUR ID - 65562 AU - Juhásová Šenitková, Ingrid - Kraus, Michal PY - 2021 TI - Case study of VOC emissions in Czech office buildings PB - American Institute of Physics Inc. CY - Spojené státy americké SN - 9780735442665 KW - Indoor Air Quality KW - office buildings KW - VOC KW - indoor environment KW - Sick Building Syndrome UR - https://aip.scitation.org/doi/10.1063/5.0105178 N2 - The paper deals with the problem of the occurrence of volatile organic compounds in the work environment, specifically in administrative public buildings in the context of the quality of the indoor environment (IAQ). The importance of indoor air quality has become an interest in research and development in the last 10 years, mainly due to the increasing quality of the airtight envelope of the building and the prevailing trend of forced ventilation. Indoor air quality is directly related to Sick Building Syndrome (SBS). The occurrence of VOC emissions within 10 selected office buildings in the South Bohemian Region in the Czech Republic is demonstrated in the practical case study. Detection of volatile organic compounds was performed using ultra-fast electronic zNose Model 4200 Analyzer based on gas chromatography with patented SAQ detector. The results of the case study demonstrate how important a quality element and the necessary implementation of the building and the design of the indoor working environment is. ER -
JUHÁSOVÁ ŠENITKOVÁ, Ingrid a Michal KRAUS. Case study of VOC emissions in Czech office buildings. Online. In Yilmaz I., Marschalko M., Drusa M. \textit{6th World Multidisciplinary Civil Engineering-Architecture-Urban Planning Symposium (WMCAUS 2021)}. 1. vyd. Spojené státy americké: American Institute of Physics Inc., 2021, s.~nestránkováno, 5 s. ISBN~978-0-7354-4266-5.
|