2022
			
	    
	
	
    Concept and Performance Analysis of Propulsion Units Intended for Distributed Ship Systems
ILLES, Ladislav; Martin JURKOVIC; Tomas KALINA; Jarmila SOSEDOVA; Piotr GORZELANCZYK et. al.Základní údaje
Originální název
Concept and Performance Analysis of Propulsion Units Intended for Distributed Ship Systems
	Autoři
ILLES, Ladislav (garant); Martin JURKOVIC; Tomas KALINA; Jarmila SOSEDOVA; Piotr GORZELANCZYK; Ondrej STOPKA (703 Slovensko, domácí) a Tibor KUBJATKO
			Vydání
 Journal of Marine Science and Engineering, MDPI, Basel, Switzerland, MDPI, Basel, St. Alban-Anlage 66, 4052 Basel, Switzerland, 2022, 2077-1312
			Další údaje
Jazyk
angličtina
		Typ výsledku
Článek v odborném periodiku
		Obor
50703 Transport planning and social aspects of transport
		Stát vydavatele
Švýcarsko
		Utajení
není předmětem státního či obchodního tajemství
		Odkazy
Impakt faktor
Impact factor: 2.900
			Kód RIV
RIV/75081431:_____/22:00002413
		Organizační jednotka
Vysoká škola technická a ekonomická v Českých Budějovicích
			UT WoS
000785110400001
		EID Scopus
2-s2.0-85127649147
		Klíčová slova anglicky
restricted draft; ducts; distributed propulsion; propeller; shallow water
		
				
				Změněno: 21. 3. 2023 19:50, Mgr. Nikola Petříková
				
		Anotace
V originále
Limited navigation depth, especially on inland waterways, is one of the main limiting factors that shorten the navigation period. Distributed propulsion systems represent an opportunity to increase the navigability of ships across critical sections of waterways characterized by limited navigation depth. In the case of distributed propulsion systems, it is necessary to examine the position of the propellers and their efficiency, suitable design, and interaction with the surroundings. In this study, self-propelled propulsion units located on the side of the ship are investigated at the level of computational fluid dynamics (CFD) analyses. Seven different types of ducts are considered for the proposed propeller geometry in order to ensure the necessary water supply, to prevent air intake, and to ensure high performance in the serial arrangement of propulsors on the side of the hull. Comparative analyses have shown that propulsion units with Ducts 5 and 6 have sufficient resistance to ventilation at a limited depth and deliver acceptable performance at low inflow and outflow rates. This feature is important in serial configurations, which confirms previous research on this issue. Performance can be further increased by reducing the duct resistance at higher speeds.