D 2017

Particulate Matter Mass Concentration in Residential Prefabricated Buildings Related to Temperature and Moisture

KRAUS, Michal a Ingrid JUHÁSOVÁ ŠENITKOVÁ

Základní údaje

Originální název

Particulate Matter Mass Concentration in Residential Prefabricated Buildings Related to Temperature and Moisture

Název česky

Koncentrace prachových částic v prefabrikovaných obytných bodovách ve vztahu k teplotě a vlhkosti

Autoři

KRAUS, Michal (203 Česká republika, domácí) a Ingrid JUHÁSOVÁ ŠENITKOVÁ (203 Česká republika, domácí)

Vydání

1. vyd. Spojené království, IOP Conference Series: Materials Science and Engineering, Volume 245, Issue 4 (World Multidisciplinary Civil Engineering-Architecture-Urban Planning Symposium 2017), od s. nestránkováno, 5 s. 2017

Nakladatel

Institute of Physics Publishing

Další údaje

Jazyk

angličtina

Typ výsledku

Stať ve sborníku

Obor

20101 Civil engineering

Stát vydavatele

Velká Británie a Severní Irsko

Utajení

není předmětem státního či obchodního tajemství

Forma vydání

elektronická verze "online"

Odkazy

Kód RIV

RIV/75081431:_____/17:00001182

Organizační jednotka

Vysoká škola technická a ekonomická v Českých Budějovicích

ISSN

Klíčová slova česky

Vnitřní prostředí; polétavý prach; teplota; vlhkost; kvalita vnitřního prostředí; panelová výstavba

Klíčová slova anglicky

Indoor environment; particulate matter; temperature; humidity; indoor air quality; prefabricated building

Štítky

Příznaky

Mezinárodní význam, Recenzováno
Změněno: 20. 4. 2018 11:19, Mgr. Blanka Mikšíková

Anotace

V originále

Building environmental audit and the assessment of indoor air quality (IAQ) in typical residential buildings is necessary process to ensure users' health and well-being. The paper deals with the concentrations on indoor dust particles (PM10) in the context of hygrothermal microclimate in indoor environment. The indoor temperature, relative humidity and air movement are basic significant factors determining the PM10 concentration. The experimental measurements in this contribution represent the impact of indoor physical parameters on the concentration of particulate matter mass concentration. The occurrence of dust particles is typical for the almost two-thirds of interiors of the buildings. Other parameters indoor environment, such as air change rate, volume of the room, roughness and porosity of the building material surfaces, static electricity, light ions and others, were set constant and they are not taken into account in this study. The mass concentration of PM10 is measured during summer season in apartment of residential prefabricated building. The values of global temperature [C] and relative humidity of indoor air [%] are also monitored. The quantity of particulate mass matter is determined gravimetrically by weighing according to CSN EN 12 341 (2014). The obtained results show that the temperature difference of the internal environment does not have a significant effect on the concentration PM10. Vice versa, the difference of relative humidity exhibits a difference of the concentration of dust particles. Higher levels of indoor particulates are observed for low values of relative humidity. The decreasing of relative air humidity about 10% caused 10 g/m3 of PM10 concentration increasing. The hygienic limit value of PM10 concentration is not exceeded at any point of experimental measurement.

Přiložené soubory

IOP_Conference_245__Issue_4__OBSAH_3.PDF
Požádat o autorskou verzi souboru
IOP_Conference_Series__TIRAZ.PDF
Požádat o autorskou verzi souboru
Particulate_Matter_Mass_Concentration_in_Residential_Prefabricated_Buildings_Related_to_Temperature_and_Moisture.pdf
Požádat o autorskou verzi souboru