KRAUS, Michal a Ingrid JUHÁSOVÁ ŠENITKOVÁ. Particulate Matter Mass Concentration in Residential Prefabricated Buildings Related to Temperature and Moisture. Online. In Marschalko M.,Drusa M.,Rybak J.,Yilmaz I.,Segalini A.,Coisson E. IOP Conference Series: Materials Science and Engineering, Volume 245, Issue 4 (World Multidisciplinary Civil Engineering-Architecture-Urban Planning Symposium 2017). 1. vyd. Spojené království: Institute of Physics Publishing, 2017, s. nestránkováno, 5 s. ISSN 1757-8981. Dostupné z: https://dx.doi.org/10.1088/1757-899X/245/4/042068.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Particulate Matter Mass Concentration in Residential Prefabricated Buildings Related to Temperature and Moisture
Název česky Koncentrace prachových částic v prefabrikovaných obytných bodovách ve vztahu k teplotě a vlhkosti
Autoři KRAUS, Michal (203 Česká republika, domácí) a Ingrid JUHÁSOVÁ ŠENITKOVÁ (203 Česká republika, domácí).
Vydání 1. vyd. Spojené království, IOP Conference Series: Materials Science and Engineering, Volume 245, Issue 4 (World Multidisciplinary Civil Engineering-Architecture-Urban Planning Symposium 2017), od s. nestránkováno, 5 s. 2017.
Nakladatel Institute of Physics Publishing
Další údaje
Originální jazyk angličtina
Typ výsledku Stať ve sborníku
Obor 20101 Civil engineering
Stát vydavatele Velká Británie a Severní Irsko
Utajení není předmětem státního či obchodního tajemství
Forma vydání elektronická verze "online"
WWW Open Access
Kód RIV RIV/75081431:_____/17:00001182
Organizační jednotka Vysoká škola technická a ekonomická v Českých Budějovicích
ISSN 1757-8981
Doi http://dx.doi.org/10.1088/1757-899X/245/4/042068
Klíčová slova česky Vnitřní prostředí; polétavý prach; teplota; vlhkost; kvalita vnitřního prostředí; panelová výstavba
Klíčová slova anglicky Indoor environment; particulate matter; temperature; humidity; indoor air quality; prefabricated building
Štítky BDP, RIV17, SCOPUS
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Blanka Mikšíková, učo 22534. Změněno: 20. 4. 2018 11:19.
Anotace
Building environmental audit and the assessment of indoor air quality (IAQ) in typical residential buildings is necessary process to ensure users' health and well-being. The paper deals with the concentrations on indoor dust particles (PM10) in the context of hygrothermal microclimate in indoor environment. The indoor temperature, relative humidity and air movement are basic significant factors determining the PM10 concentration. The experimental measurements in this contribution represent the impact of indoor physical parameters on the concentration of particulate matter mass concentration. The occurrence of dust particles is typical for the almost two-thirds of interiors of the buildings. Other parameters indoor environment, such as air change rate, volume of the room, roughness and porosity of the building material surfaces, static electricity, light ions and others, were set constant and they are not taken into account in this study. The mass concentration of PM10 is measured during summer season in apartment of residential prefabricated building. The values of global temperature [C] and relative humidity of indoor air [%] are also monitored. The quantity of particulate mass matter is determined gravimetrically by weighing according to CSN EN 12 341 (2014). The obtained results show that the temperature difference of the internal environment does not have a significant effect on the concentration PM10. Vice versa, the difference of relative humidity exhibits a difference of the concentration of dust particles. Higher levels of indoor particulates are observed for low values of relative humidity. The decreasing of relative air humidity about 10% caused 10 g/m3 of PM10 concentration increasing. The hygienic limit value of PM10 concentration is not exceeded at any point of experimental measurement.
Anotace česky
Environmentální audit budov a hodnocení kvality vnitřního prostředí (IAQ) v obytných budovách je nezbytným procesem zajišťující zdraví a pohodu uživatelů. Příspěvek se zabývá koncentrací polétavého prachu (PM10) v kontextu tepelně-vlhkostního mikroklimatu vnitřního prostředí. Teplota vnitřního vzduchu, relativní vlhkost a rychlost proudění vzduchu jsou základními determinanty koncentrace polétavého prachu PM10. Experimentální měření zkoumá vliv fyzikálních parametrů na hmotnostní koncentrace prachových částic. Výskyt polétavého prachu je typický pro téměř dvě třetiny interiérů budov. Další parametry jako je rychlost proudění vzduchu, objem místnosti, drsnost a poréznost povrchů stavebních materiálů, statická elektřiny, lehké ionty a další jsou udržovány konstantní a nejsou zohledněny. Koncentrace pevných částic PM10 jsou měřeny v letní sezóně v bytě situovaném v panelové prefabrikované budově. Rovněž jsou monitorovány hodnoty teploty a relativní vlhkosti. Množství polétavého prachu je určena gravimetrickým vážením dle ČSN EN 12 341 (2014). Získané výsledky ukazují, že teplotní diference nemá vliv na koncentrace prachových částic. Naopak, změny relativní vlhkosti reflektují změny koncentrace polétavého prachu PN10. Vysoké hodnoty relativní vlhkosti reflektují nízké koncentrace polétavého prachu. Snižování relativní vlhkosti o 10 % způsobuje nárůst koncentrací polétavého prachu o 10 g/m3. Hygienické limity nejsou překročeny v žádné bodě měření.
VytisknoutZobrazeno: 24. 6. 2024 04:55