D 2017

Indoor Environment in Residential Prefabricated Buildings

KRAUS, Michal and Ingrid JUHÁSOVÁ ŠENITKOVÁ

Basic information

Original name

Indoor Environment in Residential Prefabricated Buildings

Name in Czech

Vnitřní prostředí v prefabrikovaných obytných budovách

Authors

KRAUS, Michal (203 Czech Republic, guarantor, belonging to the institution) and Ingrid JUHÁSOVÁ ŠENITKOVÁ (703 Slovakia, belonging to the institution)

Edition

1. vyd. Spojené království, IOP Conference Series: Materials Science and Engineering, Volume 245, Issue 4 (World Multidisciplinary Civil Engineering-Architecture-Urban Planning Symposium 2017), p. nestránkováno, 7 pp. 2017

Publisher

Institute of Physics Publishing

Other information

Language

English

Type of outcome

Stať ve sborníku

Field of Study

20101 Civil engineering

Country of publisher

United Kingdom of Great Britain and Northern Ireland

Confidentiality degree

není předmětem státního či obchodního tajemství

Publication form

electronic version available online

References:

Open Access

RIV identification code

RIV/75081431:_____/17:00001181

Organization unit

Institute of Technology and Business in České Budějovice

ISSN

DOI

http://dx.doi.org/10.1088/1757-899X/245/4/042072

Keywords (in Czech)

Indoor air quality; indoor environment; prefabricated building; indoor air temperature; relative humidity; volatile organic compounds

Keywords in English

Kvalita vnitřního vzduchu; vnitřní prostředí; prefabrikovaná budova; teplota vnitřního vzduchu; relativní vlhkost; těkavé organické látky

Tags

BDP, RIV17, SCOPUS

Tags

International impact, Reviewed
Změněno: 20/4/2018 11:19, Mgr. Blanka Mikšíková

Abstract

ORIG CZ

V originále

The contribution presents results of the experimental measurement of indoor air quality in residential prefabricated buildings. People spend about 90% of their life in the indoor environment of buildings. Hygrothermal parameters and indoor air quality are the essential component that define the quality of the indoor environment. The results of case study characterize the quality of the indoor environment of the ordinary occupants in housing unit of residential prefabricated building. A current problem of revitalized prefabricated buildings is inadequate air exchange and related thereto to poor indoor air quality. The experimental measurements were carried out just before and at the beginning of the heating season (from 1st October to 30th November 2016). Heating season was launched in the middle of experimental measurement. The wireless indoor sensor Elgato Eve Room was used for measurements. The obtained values of indoor air temperature [C], relative humidity [%] and indoor air quality [ppm] are describe and analysis in this study. The results of the study indicate that the values of temperature and indoor air quality meet optimal levels during the experiment with nuances. The mean air temperature in the indoor environment is 22.43 C. The temperature of the indoor environment is held at the optimum level (18-24 C) for 94.50% time of the experimental measurements. In addition, the indoor air quality in the context of the content of harmful volatile organic compounds (VOCs) has been excellent for almost 91% time of the total experiment. However, the values of relative humidity were less than the optimum value nearly 40% of the total observed time. The mean 10-minutes values of relative humidity during the heating season is about 10% lower than the mean 10-minutes relative humidity before the heating season.

In Czech

Příspěvek prezentuje výsledky experimentálního měření kvality vnitřního prostředí v prefabrikovaných obytných budovách. Lidí tráví až 90 % svého času ve vnitřním prostředí. Tepelně-vlhkostní parametry a kvalita vnitřního vzduchu jsou základními parametry definující kvalitu vnitřního prostředí. Výsledky případové studie reflektují kvalitu vnitřního prostředí v bytové jednotce panelového domu při běžném užívání. Současným problémem revitalizovaných panelových budov je nedostatečná výměna vzduchu a s tím související špatná kvalita vnitřního prostředí. Experimentální měření bylo provedeno před a v průběhu topné sezóny (1. říjen - 30. listopad 2016). Topná sezóna byla zahájena v polovině měření. Pro měření byl použit bezdrátový senzor Elgato Eve Room. V příspěvku jsou popsány a analyzovány průběhy teploty vnitřního vzduchu [°C], hodnoty relativní vlhkosti vzduchu [%] a kvalita vnitřního prostředí [ppm]. Výsledky studie naznačují, že hodnoty teploty a kvality vnitřního prostředí splňují optimální hodnoty s mírnými nuancemi. Průměrná teplota ve vnitřním prostředí je 22,43 °C. Teplota vnitřního prostředí je udržována v optimálních mezích (18-24 °C) po více než 94,50 % doby měření. Z hlediska obsahu těkavých organických látek (VOC), vnitřní prostředí bylo vyhovující více než 91 % doby experimentu. Naměřené hodnoty relativní vlhkosti jsou nižší než optimální míra relativní vlhkosti téměř po 40 % doby měření. Průměrná 10-minutová relativní vlhkost v průběhu topné sezóny je o 10 % nižší než průměrná 10-minutová relativních vlhkost před topnou sezónou.
Displayed: 22/11/2024 06:16