KRAUS, Michal. Pairwaise Comparision of Determinants of Building Airtightness (Pairwaise Comparision of Determinant of Building Airtightness). In 16th International Multidisciplinary Scientific GeoConference SGEM 2016. 1. vyd. Sofia (Bulharsko): STEF92 TECHNOLOGY LTD, 2016, p. 577-584. ISBN 978-619-7105-79-7. Available from: https://dx.doi.org/10.5593/SGEM2016/HB63/S10.074.
Other formats:   BibTeX LaTeX RIS
Basic information
Original name Pairwaise Comparision of Determinants of Building Airtightness
Name in Czech Párové srovnání determinantů vzduchotěsnosti budov
Authors KRAUS, Michal (203 Czech Republic, guarantor, belonging to the institution).
Edition 1. vyd. Sofia (Bulharsko), 16th International Multidisciplinary Scientific GeoConference SGEM 2016, p. 577-584, 8 pp. 2016.
Publisher STEF92 TECHNOLOGY LTD
Other information
Original language English
Type of outcome Proceedings paper
Field of Study 20101 Civil engineering
Country of publisher Bulgaria
Confidentiality degree is not subject to a state or trade secret
Publication form printed version "print"
WWW SGEM library
RIV identification code RIV/75081431:_____/16:00001021
Organization unit Institute of Technology and Business in České Budějovice
ISBN 978-619-7105-79-7
ISSN 1314-2704
Doi http://dx.doi.org/10.5593/SGEM2016/HB63/S10.074
Keywords (in Czech) vzduchotěsnost; průvzdušnost; obálka budovy; párové srovnání; fullerův trojúhelník
Keywords in English airtightness; air permeability; building envelope; pairwise comparison; fuller’s triangle
Tags KST6, RIV17, WOS
Tags International impact, Reviewed
Changed by Changed by: Mgr. Blanka Mikšíková, učo 22534. Changed: 20/4/2018 08:08.
Abstract
Contemporary tendencies of building constructions are mainly concentrate on saving energy and reducing greenhouse gas emissions in accordance with the rules of sustainable development. The significance of the airtightness of building envelope is demonstrably non-negligible for energy-efficient constructions. Uncontrolled flow of air through the building envelopes negatively influences the energy balance of the building. In some cases, it reduces the life of the structure and increases the risk of defects, such as condensation of water vapor and the occurrence of mold. High quality and airtight building envelope can reduce the demand for heating by up to 10 %. The paper deals with the determination of significant factors of building airtightness using the method of pairwise comparison (Fuller’s triangle). The method of Fuller’s triangle is based on select preferred factor of a pair of factors. The newly acquired results are compared with previously obtained information based on statistical methods (statistical Test of independence) and quality management tools (Cause and Effect Diagram and brainstorming). Implementation of new knowledge into the building practice can significantly affect the quality of envelope already in pre-production phase and design phase.
Abstract (in Czech)
Trendy současné výstavby se zaměřují především na úsporu energie a redukci emisí skleníkových plynů v souladu s principy trvale udržitelného rozvoje. Vzduchotěsnost je jedním ze základních předpokladů energeticky efektivní výstavby. Nekontrolovatelné proudění vzduchu skrze obvodový plášť negativně ovlivňuje energetickou bilanci budovy. V některých případech také nekontrolovatelný průtok vzduchu snižuje životnost konstrukce a zvyšuje pravděpodobnost výskytu poruchy, jako je kondenzace vodní páry uvnitř konstrukce nebo výskyt plísní. Kvalitně provedená vzduchotěsná obálka budovy umožňuje snížit potřebu tepla na vytápění až o 10 %. Příspěvek se zabývá stanovením významných faktorů vzduchotěsnosti obálky budovy, tzv. determinantů, pomocí metody párového srovnání (Fullerův trojúhelník). Metoda Fullerova trojúhelníku je založena na výběru preferovanějšího faktoru z každého páru posuzovaných faktorů. Získané výsledky jsou komparovány s již dříve získanými a publikovanými výsledky získaných pomocí statistických metod (statistický test nezávislosti) a pomocí nástrojů řízení kvality (Diagram příčin a následků, brainstorming). Zavedení nových poznatků do praxe může významně ovlivnit kvalitu obálky budovy již v předvýrobní fázi stavby.
PrintDisplayed: 9/6/2024 01:56