D 2024

The Effect of Ventilation in Residential Buildings on The Indoor Environment

PLACHÝ, Jan; Pavlína CHARVÁTOVÁ and Tomáš NAVARA

Basic information

Original name

The Effect of Ventilation in Residential Buildings on The Indoor Environment

Name in Czech

Vliv větrání v obytných budovách na vnitřní prostředí

Authors

Edition

1. vyd. Spojené státy americké, AIP Conference Proceedings, Volume 3126, issue 1: 28th International Meeting of Thermophysics 2023, p. nestránkováno, 9 pp. 2024

Publisher

American Institute of Physics Inc.

Other information

Language

English

Type of outcome

Proceedings paper

Field of Study

20100 2.1 Civil engineering

Country of publisher

United States of America

Confidentiality degree

is not subject to a state or trade secret

Publication form

electronic version available online

References:

Marked to be transferred to RIV

Yes

RIV identification code

RIV/75081431:_____/24:00002787

Organization unit

Institute of Technology and Business in České Budějovice

ISBN

978-0-7354-4873-5

ISSN

EID Scopus

Keywords (in Czech)

vytápění; větrání a klimatizace; termografie; termokamera

Keywords in English

Heating; ventilation and air-conditioning; Thermography; Cameras

Tags

Changed: 25/2/2025 11:58, Ing. Barbora Langšádlová

Abstract

In the original language

The paper deals with the issue of mold growth in an apartment building. It is a panel house. The ETICS contact insulation system was installed on the house and the windows were replaced. In order to find out the cause of the mold, the apartment was diagnosed. The apartment was diagnosed using thermography. Thermal bridges were detected using an infrared camera. These thermal bridges did not lead to mold growth. The cause of the mold was not the insulation of the building, but the poor use of the apartment by the tenants. The apartment was insufficiently ventilated.

In Czech

Příspěvek se zabývá problematikou vzniku plísní v bytovém domě. Jedná se o panelový dům. Na dome byl proveden kontaktní zateplovací systém ETICS a vyměněna okna. Pro zjištění příčiny vzniku plísně byla provedena diagnostika bytu. V byte byka provedena diagnostika pomocí termografie. Pomocí infračervené kamery (infrared camera) byly zjištěny tepelné mosty. Tyto tepelné mosty nevedly ke vzniku plísní. Příčinou vzniku plísní nebylo zateplení objektu, ale špatné užívání bytu nájemníky. Byt byl nedostatečně větrán.