J 2021

Selective Laser Melting of PA 2200 for Hip Implant Applications: Finite Element Analysis, Process Optimization, and Morphological and Mechanical Characterization

PACURAR, Razvan; Petru BERCE; Anna PETRILAK; Ovidiu NEMES; Cristina Stefana Miron BORZAN et al.

Basic information

Original name

Selective Laser Melting of PA 2200 for Hip Implant Applications: Finite Element Analysis, Process Optimization, and Morphological and Mechanical Characterization

Authors

PACURAR, Razvan; Petru BERCE; Anna PETRILAK; Ovidiu NEMES; Cristina Stefana Miron BORZAN; Marta HARNIČÁROVÁ and Ancuta PACURAR

Edition

Materials, Basel, Switzerland, MDPI, 2021, 1996-1944

Other information

Language

English

Type of outcome

Article in a journal

Field of Study

20501 Materials engineering

Country of publisher

Switzerland

Confidentiality degree

is not subject to a state or trade secret

References:

Impact factor

Impact factor: 3.748

Marked to be transferred to RIV

Yes

RIV identification code

RIV/75081431:_____/21:00002158

Organization unit

Institute of Technology and Business in České Budějovice

Keywords in English

selective laser sintering; hip implants; acetabular liner; surface roughness; compression; finite element analysis; contact pressure; paraxylene immersion

Tags

Changed: 8/10/2021 09:25, Mgr. Nikola Petříková

Abstract

In the original language

"Polyamide 12 (PA 22000) is a well-known material and one of the most biocompatible materials tested and used to manufacture customized medical implants by selective laser sintering technology. To optimize the implants, several research activities were considered, starting with the design and manufacture of test samples made of PA 2200 by selective laser sintering (SLS) technology, with different processing parameters and part orientations. The obtained samples were subjected to compression tests and later to SEM analyses of the fractured zones, in which we determined the microstructural properties of the analyzed samples. Finally, an evaluation of the surface roughness of the material and the possibility of improving the surface roughness of the realized parts using finite element analysis to determine the optimum contact pressure between the component made of PA 2200 by SLS and the component made of TiAl6V4 by SLM was performed."