Energy Effciency of Novel Interior Surface Layer with Improved Thermal Characteristics and Its Effect on Hygrothermal Performance of Contemporary Building Envelopes

FOŘT, Jan; Jiří ŠÁL; Jan KOČÍ and Robert ČERNÝ

Basic information

Original name

Energy Effciency of Novel Interior Surface Layer with Improved Thermal Characteristics and Its Effect on Hygrothermal Performance of Contemporary Building Envelopes

Authors

FOŘT, Jan; Jiří ŠÁL; Jan KOČÍ and Robert ČERNÝ

Edition

Energies, Switzerland, MDPI AG, 2020, 1996-1073

Other information

Language

English

Type of outcome

Article in a journal

Field of Study

20505 Composites

Country of publisher

Switzerland

Confidentiality degree

is not subject to a state or trade secret

References:

Impact factor

Impact factor: 3.004

Marked to be transferred to RIV

Yes

RIV identification code

RIV/75081431:_____/20:00002103

Organization unit

Institute of Technology and Business in České Budějovice

EID Scopus

Keywords in English

plaster; thermal energy storage; computation simulation; recuperation heat; passive cooling; climate

Tags

Changed: 20/4/2022 12:22, Mgr. Nikola Petříková

Abstract

In the original language

Facing the consequences of climate change and fuel price rises, the achievement of the requirements for low-energy consumption of buildings has become a challenging issue. On top of that, increased demands on indoor hygrothermal conditions usually require the utilization of additional heating, ventilation, and air-conditioning (HVAC) systems to maintain a comfortable environment. On this account, several advanced and modern materials are widely investigated as a promising way for reduction of the buildings’ energy consumption including utilization of passive heating/cooling energy. However, the efficiency and suitability of passive strategies depending on several aspects including the influence of location, exterior climatic conditions, load-bearing materials used, and insulation materials applied. The main objective of this study consists of the investigation of the energy performance benefits gained by the utilization of advanced materials in plasters by computational modeling. Results obtained from a computational simulation reveal the capability of the studied passive cooling/heating methods on the moderation of indoor air quality together with the reduction of the diurnal temperature fluctuation. Achieved results disclose differences in terms of energy savings for even small variation in outdoor climate conditions. Additionally, the effectivity of passive cooling/heating alters considerably during the summer and winter periods. Based on the analysis of simulated heat fluxes, the potential energy savings related to improved thermal properties of the applied plaster layer reached up to 12.08% and thus represent an interesting passive solution towards energy sustainability to meet the criteria on modern buildings.