2020
Interior thermal insulation systems based on wood fiberboards: experimental analysis and computational assessment of hygrothermal and energy performance in the Central European climate
KOČÍ, Václav; Miloš JERMAN; Zbyšek PAVLÍK; Jiří MADĚRA; Jaroslav ŽÁK et al.Basic information
Original name
Interior thermal insulation systems based on wood fiberboards: experimental analysis and computational assessment of hygrothermal and energy performance in the Central European climate
Name in Czech
Vnitřní tepelně izolační systémy na bázi dřevovláknitých desek: experimentální analýza a výpočetní hodnocení tepelně vlhkostní a energetické náročnosti ve středoevropském klimatu
Authors
KOČÍ, Václav; Miloš JERMAN; Zbyšek PAVLÍK; Jiří MADĚRA; Jaroslav ŽÁK and Robert ČERNÝ
Edition
Energy and buildings, Lausanne, Elsevier Science, 2020, 0378-7788
Other information
Language
English
Type of outcome
Article in a journal
Field of Study
20505 Composites
Country of publisher
Switzerland
Confidentiality degree
is not subject to a state or trade secret
References:
Impact factor
Impact factor: 5.879
Marked to be transferred to RIV
Yes
RIV identification code
RIV/75081431:_____/20:00001912
Organization unit
Institute of Technology and Business in České Budějovice
UT WoS
Keywords (in Czech)
růst biofilmů; výpočetní modelování; teplotně vlhkostní vzorce; cihlové zdivo; vnitřní tepelná izolace; klimatické údaje; minerální vlna; dřevovláknitá deska
Keywords in English
biofilms growth; computational modeling; hygrothermal patterns; brick masonry; interior thermal insulation; climatic data; mineral wool; wood fiber board
Changed: 7/4/2021 09:04, Mgr. Milada Šanderová
In the original language
Two interior thermal insulation systems based on wood fiberboards are analyzed. The first system is com- posed of soft and hard fiberboards, the second one utilizes a capillary active fiberboard with incorporated water vapor retarder. The hygrothermal and energy performance of the systems in the climatic conditions of Central Europe is assessed using a combination of experimental and computational methods. A labora- tory critical experiment is performed at first. The measured temperature and moisture profiles are then used for the validation of computational model of coupled heat and moisture transport, which is applied for hygrothermal and energy simulations. After the successful validation procedure, the model is used for the annual assessments. The energy assessment of the two-layer system shows excellent results from the point of view of energy savings (79 % improvement) but its hygrothermal assessment reveals possi- ble shortages related to excessive hygric straining of the wall on the exterior side. The capillary active insulation system with water vapor retarder, which is able to keep moisture in the envelope within the hygroscopic range, exhibits only slightly worse energy performance (66 % improvement) but much better hygric performance than the two-layer system.
In Czech
Analyzovány jsou dva vnitřní tepelně izolační systémy na bázi dřevovláknitých desek. První systém se skládá z měkkých a tvrdých dřevovláknitých desek, druhý využívá kapilární aktivní dřevovláknité desky se zabudovaným retardérem vodní páry. Hygrotermální a energetická náročnost systémů v klimatických podmínkách střední Evropy je hodnocena pomocí kombinace experimentálních a výpočetních metod. Nejprve se provede laboratorní kritický experiment. Měřené teplotní a vlhkostní profily se poté použijí pro validaci výpočtového modelu vázaného přenosu tepla a vlhkosti, který se použije pro hydrotermální a energetické simulace. Po úspěšném postupu validace se model použije pro roční hodnocení. Energetické hodnocení dvouvrstvého systému vykazuje vynikající výsledky z hlediska energetických úspor (zlepšení o 79%), ale jeho teplotně vlhkostní hodnocení odhaluje možné nedostatky související s nadměrným tlakovým namáháním stěny na vnější straně. Kapilární aktivní izolační systém s retardérem vodní páry, který je schopen udržovat vlhkost v obalu v hygroskopickém rozsahu, vykazuje pouze o něco horší energetický výkon (zlepšení o 66%), ale mnohem lepší hygrický výkon než dvouvrstvý systém.