FOŘT, Jan, Jan KOČÍ, Jaroslav POKORNÝ and Robert ČERNÝ. Influence of Superabsorbent Polymers on Moisture Control in Building Interiors. Energies. Switzerland: MDPI, vol. 13, No 8, p. 1-13. ISSN 1996-1073. doi:10.3390/en13082009. 2020.
Other formats:   BibTeX LaTeX RIS
Basic information
Original name Influence of Superabsorbent Polymers on Moisture Control in Building Interiors
Name in Czech Vliv superabsorpčních polymerů na kontrolu vlhkosti v interiérech budov
Authors FOŘT, Jan (203 Czech Republic, guarantor, belonging to the institution), Jan KOČÍ (203 Czech Republic), Jaroslav POKORNÝ (203 Czech Republic, belonging to the institution) and Robert ČERNÝ (203 Czech Republic).
Edition Energies, Switzerland, MDPI, 2020, 1996-1073.
Other information
Original language English
Type of outcome Article in a journal
Field of Study 20505 Composites
Country of publisher Switzerland
Confidentiality degree is not subject to a state or trade secret
WWW URL
RIV identification code RIV/75081431:_____/20:00001900
Organization unit Institute of Technology and Business in České Budějovice
Doi http://dx.doi.org/10.3390/en13082009
UT WoS 000538041800152
Keywords (in Czech) omítka; relativní vlhkost; superabsorpční polymer; zmírnění vlhkosti; výpočetní modelování
Keywords in English plaster; relative humidity; superabsorbent polymer; moisture moderation; computational modeling
Tags RIV20, SHM, WOS
Changed by Changed by: Ing. Barbora Langšádlová, učo 16591. Changed: 28/1/2021 09:09.
Abstract
Moisture loads in building interiors are accompanied by a deterioration of the indoor air quality. Such a phenomenon may induce serious health risks for building inhabitants as well as degradation of furnishing. Unfortunately, the employment of additional heat, ventilation and air conditioning (HVAC) devices does not comply with the sustainability principle due to increased energy consumption, thus cannot be viewed as an efficient solution. This study deals with the use of superabsorbent polymers (SAP) in cement-lime plasters, thus extends the current state of knowledge and outlines further possible development of novel moisture responsive plasters since lightweight aggregates do not provide the desired performance. To be specific, this paper contemplates the experimental analysis of novel plasters modified by 0.5, 1 and 1.5 wt. % of SAP to obtain input parameters for computational modeling. Based on the obtained outputs, the incorporation of SAP admixture resulted in a substantial increase in moisture transport properties including the water absorption coefficient and water vapor diffusion properties. The performed computational modeling revealed a considerable reduction of relative humidity fluctuations, thus mitigation of potential health issues associated with undesired moisture content in building interiors. Achieved results indicate that the SAP enhanced plasters have substantial passive moisture buffering performance and thus may contribute to the improvement of indoor air quality.
Abstract (in Czech)
Vlhkostní zatížení v interiérech budov je doprovázeno zhoršením kvality vnitřního vzduchu. Takový jev může vyvolat vážná zdravotní rizika pro obyvatele budov i zhoršení vybavení. Využití přídavných zařízení pro topení, ventilaci a klimatizaci (HVAC) bohužel nesplňuje princip udržitelnosti kvůli zvýšené spotřebě energie, a proto jej nelze považovat za efektivní řešení. Tato studie se zabývá použitím superabsorpčních polymerů (SAP) v cemento-vápenných omítkách, čímž rozšiřuje současný stav znalostí a nastiňuje další možný vývoj nových omítek reagujících na vlhkost, protože lehké agregáty neposkytují požadovaný výkon. Konkrétně tento článek uvažuje experimentální analýzu nových náplastí modifikovaných 0,5, 1 a 1,5 hm. % SAP k získání vstupních parametrů pro výpočetní modelování. Na základě získaných výstupů mělo začlenění přísady SAP za následek podstatné zvýšení transportních vlastností vlhkosti, včetně koeficientu absorpce vody a difúze vodních par. Provedené výpočtové modelování odhalilo značné snížení kolísání relativní vlhkosti, čímž zmírnilo potenciální zdravotní problémy spojené s nežádoucím obsahem vlhkosti v interiérech budov. Dosažené výsledky naznačují, že omítky se zvýšenou SAP mají podstatnou účinnost tlumení pasivní vlhkosti a mohou tak přispívat ke zlepšení kvality vnitřního vzduchu.
PrintDisplayed: 29/3/2024 00:00