2019
Defects of the building and its remediation – Case study: Elementary school Vodňany
DĚDIČ, MartinBasic information
Original name
Defects of the building and its remediation – Case study: Elementary school Vodňany
Name in Czech
Poruchy stavby a její sanace - Případová studie: Základní škola Vodňany
Authors
DĚDIČ, Martin
Edition
279. vyd. Francie, MATEC Web of Conferences, 279 (2019): 10th International Scientific Conference Building Defects (Building Defects 2018), p. nestránkováno, 6 pp. 2019
Publisher
EDP Sciences
Other information
Language
English
Type of outcome
Proceedings paper
Field of Study
20100 2.1 Civil engineering
Country of publisher
France
Confidentiality degree
is not subject to a state or trade secret
Publication form
electronic version available online
References:
Marked to be transferred to RIV
Yes
RIV identification code
RIV/75081431:_____/19:00001852
Organization unit
Institute of Technology and Business in České Budějovice
ISSN
UT WoS
Keywords (in Czech)
Sedání základové zeminy; Poruchy podlah; Poruchy příček
Keywords in English
Settling of the foundation; Floor faults; Partition faults
Changed: 15/12/2020 14:27, Kateřina Nygrýnová
In the original language
"The aim of the paper is to provide information on the defects in the construction of the elementary school in Vodňany. The building of the elementary school dates back to 1973. It is a reinforced concrete columns skeleton with a filling peripheral and internal dividing brick masonry. The object is used by the primary school and is permanently used and maintained. The extent of structural damage is stabilized in the current state and is not an immediate risk to the user of the object. It concers only non-load-bearing structures (floor and partitions), the vertical load-bearing structures do not show a decrease and therefore the stability of the whole building is not compromised. However, actual damage complicates operation of elementary school and is very non-aesthetic. Concurrent damage to structures is the result of vertical deformation of the foundation soil. Vertical deformation of the foundation soil - sediment is the result of the building construction on a former creek which was not properly excavated and covered with a suitable backfill. Subsidence further strengthens imperfect drained rainwater from the roof of the building and leakage of rainwater drains. "
In Czech
Cílem příspěvku je poskytnout informace o závadách na stavbě základní školy ve Vodňanech. Budova základní školy pochází z roku 1973. Jedná se o železobetonový sloupový skelet s výplňovým obvodovým a vnitřním dělícím cihlovým zdivem. Objekt je využíván základní školou a je trvale používán a udržován. Rozsah strukturálního poškození je v současném stavu stabilizovaný a nepředstavuje bezprostřední riziko pro uživatele objektu. Zahrnuje pouze nenosné konstrukce (podlaha a příčky), svislé nosné konstrukce nevykazují pokles, a proto není ohrožena stabilita celého objektu. Skutečné poškození však komplikuje chod základní školy a je velmi neestetické. Souběžné poškození konstrukcí je výsledkem svislé deformace základové půdy. Svislá deformace základové půdy - sedimentu je výsledkem konstrukce budovy na bývalém potoce, který nebyl řádně vyhlouben a zasypán vhodným zásypem. Pokles dále posiluje nedokonalou odváděnou dešťovou vodu ze střechy budovy a únik odtoků dešťové vody.