D 2019

Assessment of the condition, cause and possible other defects on the wooden facąde of ThermoWood in terms of blackening the entire facade of the family house

DĚDIČ, Martin

Basic information

Original name

Assessment of the condition, cause and possible other defects on the wooden facąde of ThermoWood in terms of blackening the entire facade of the family house

Name in Czech

Posouzení stavu, příčiny a případných dalších vad na dřevěné fasádě ThermoWood z hlediska zčernání celé fasády rodinného domu

Authors

DĚDIČ, Martin (203 Czech Republic, guarantor, belonging to the institution)

Edition

1. vyd. Spojené království, IOP Conference Series: Materials Science and Engineering, p. 1-5, 5 pp. 2019

Publisher

Institute of Physics Publishing

Other information

Language

English

Type of outcome

Proceedings paper

Field of Study

20101 Civil engineering

Country of publisher

United Kingdom of Great Britain and Northern Ireland

Confidentiality degree

is not subject to a state or trade secret

Publication form

electronic version available online

RIV identification code

RIV/75081431:_____/19:00001602

Organization unit

Institute of Technology and Business in České Budějovice

ISSN

Keywords (in Czech)

Dřevěný obklad; dřevokazné plísně

Keywords in English

Wood cladding; wood decaying mold
Changed: 16/10/2019 14:19, Ing. Anna Palokha

Abstract

V originále

The aim of the paper was to provide information about defects and causes of faults on the wooden facade of ThermoWood. The examined failure is the blackening of wooden elements on the entire area of the family house facade. The family house is now in a finished form and is therefore permanently used for housing people. Current damage does not jeopardize the stability of the object. A test sample of the blackened facade from the north-east side of the building at locations available and with a predominant blackening ratio was taken to determine the cause of the failure. The evaluation was based on general technical requirements for carrying out the work related to the implementation of the facade, technological details. Local examination of the facade revealed that the blackening occurs across the surface and shows signs of fungus. For this reason, a sample of the facade was taken from the north-eastern part and the opinion of the Czech Mycological Society was requested based on the photo documentation including the description of the impregnation used. At the end of the paper, we propose a comprehensive solution to the facade failure with the provision of the disposal and elimination of possible sources supporting the mold formation.