KRAUS, Michal and Ingrid JUHÁSOVÁ ŠENITKOVÁ. Material VOC Emissions and Indoor Air Quality Simulation. Online. In Yilmaz I.,Marschalko M.,Drusa M.,Dabija A.M.,Toksoz D.,Niemiec D. IOP Conference Series: Materials Science and Engineering, Volume 603, Issue 5 (4th World Multidisciplinary Civil Engineering-Architecture-Urban Planning Symposium, WMCAUS 2019). 1. vyd. Spojené království: Institute of Physics Publishing, 2019, p. nestránkováno, 7 pp. ISSN 1757-8981. Available from: https://dx.doi.org/10.1088/1757-899X/603/5/052082.
Other formats:   BibTeX LaTeX RIS
Basic information
Original name Material VOC Emissions and Indoor Air Quality Simulation
Name in Czech VOC emise z materiálů a simulace kvality vnitřního ovzduší
Authors KRAUS, Michal (203 Czech Republic, guarantor, belonging to the institution) and Ingrid JUHÁSOVÁ ŠENITKOVÁ (703 Slovakia, belonging to the institution).
Edition 1. vyd. Spojené království, IOP Conference Series: Materials Science and Engineering, Volume 603, Issue 5 (4th World Multidisciplinary Civil Engineering-Architecture-Urban Planning Symposium, WMCAUS 2019), p. nestránkováno, 7 pp. 2019.
Publisher Institute of Physics Publishing
Other information
Original language English
Type of outcome Proceedings paper
Field of Study 20101 Civil engineering
Country of publisher United Kingdom of Great Britain and Northern Ireland
Confidentiality degree is not subject to a state or trade secret
Publication form electronic version available online
RIV identification code RIV/75081431:_____/19:00001598
Organization unit Institute of Technology and Business in České Budějovice
ISSN 1757-8981
Doi http://dx.doi.org/10.1088/1757-899X/603/5/052082
Keywords (in Czech) Kvalita vnitřního ovzduší; simulace; těkavé organické látky; materiál
Keywords in English Indoor air quality; simulation; volatile organic compounds; rate of ventilation; material
Tags BDP, RIV19, SCOPUS
Tags International impact, Reviewed
Changed by Changed by: Ing. Anna Palokha, učo 18083. Changed: 16/10/2019 14:27.
Abstract
The contribution reports on a simulation study of indoor air quality in relation to different ventilation rates specified for 3 categories of the indoor environment according to EN 15 251. Indoor air quality and energy management are often at the opposite ends of the building management spectrum. The buildings are polluted by occupants of the building themselves. The indoor air quality can be expressed at the required level of ventilation or Carbon Dioxide (CO2) concentration. Actually, the indoor air quality is influenced by emission from building surface materials and furnishing, occupants and their activities. VOCs play an important role in the indoor air quality evaluation process. VOC emissions adversely affect both occupant comfort and health. Most of the health hazards associated with VOC emissions occur during the first few weeks of building use. The Indoor Air Quality Emission Simulation Tool developed by National Research Council is used for simulating the VOCs emission impact of selected materials based on the amount of materials used and the ventilation rates in a model room, in this case study. IA-Quest predicts the emission of VOCs from building surface materials and furnishings, helping to select low-emission materials and effective ventilation strategies. The results showed the benefit of removing the increased amount of TVOC generated in time of the unoccupied period. The differences in TVOC concentrations were not obvious between two higher ventilation conditions (2.00 and 1.40 l/s.m2). More significant difference was estimated between categories A, B and category C (0.80 l/s.m2).
Abstract (in Czech)
Příspěvek pojednává o simulační studii kvality vnitřního ovzduší ve vztahu k různým intenzitám větrání specifikovaným pro 3 kategorie vnitřního prostředí podle EN 15 251. Kvalita vnitřního ovzduší a správa energické náročnosti jsou často na opačných koncích spektra správy budov. Budovy jsou znečištěny samotnými obyvateli budovy. Kvalitu vnitřního vzduchu lze vyjádřit při požadované úrovni větrání nebo koncentrací oxidu uhličitého (CO2). Ve skutečnosti je kvalita vnitřního ovzduší ovlivňována emisemi z povrchových materiálů a vybavení budov, obyvateli a jejich činností. VOC hrají důležitou roli v procesu hodnocení kvality vnitřního ovzduší. Emise VOC nepříznivě ovlivňují pohodlí a zdraví uživatelů budovy. Většina zdravotních rizik spojených s emisemi VOC se vyskytuje během prvních několika týdnů používání budovy. V této případové studii se pro simulaci dopadu emisí VOC vybraných materiálů na základě množství použitých materiálů a míry ventilace v modelové místnosti používá simulační nástroj pro emise kvality vnitřního vzduchu. IA-Quest předpovídá emise VOC ze stavebních materiálů a zařízení budov, což pomáhá při výběru materiálů s nízkými emisemi a účinnému návrhu strategií větrání. Výsledky ukázaly přínos odstranění zvýšeného množství TVOC generovaného v době neobsazené doby. Rozdíly v koncentracích TVOC nebyly patrné mezi dvěma vyššími ventilačními podmínkami (2,00 a 1,40 l / s.m2). Významnější rozdíl byl odhadnut mezi kategoriemi A, B a C (0,80 l/s.m2).
PrintDisplayed: 8/6/2024 13:34