D 2018

Impact of hygro-thermal conditions on indoor air quality

KRAUS, Michal and Ingrid JUHÁSOVÁ ŠENITKOVÁ

Basic information

Original name

Impact of hygro-thermal conditions on indoor air quality

Name in Czech

Dopad hygrotermických podmínek na kvalitu vnitřního vzduchu

Authors

KRAUS, Michal (203 Czech Republic, guarantor, belonging to the institution) and Ingrid JUHÁSOVÁ ŠENITKOVÁ (703 Slovakia, belonging to the institution)

Edition

1. vyd. Bulharsko, 18th International Multidisciplinary Scientific GeoConference, SGEM 2018: Volume 18 Nano, Bio and Green and Space - Technologies for a Sustainable Future, Issue 6.3, p. 589-596, 8 pp. 2018

Publisher

STEF92 Technology Ltd.

Other information

Language

English

Type of outcome

Stať ve sborníku

Field of Study

20100 2.1 Civil engineering

Country of publisher

Bulgaria

Confidentiality degree

není předmětem státního či obchodního tajemství

Publication form

printed version "print"

RIV identification code

RIV/75081431:_____/18:00001369

Organization unit

Institute of Technology and Business in České Budějovice

ISBN

978-619-7408-52-2

DOI

http://dx.doi.org/10.5593/sgem2018/6.3

Keywords (in Czech)

Korelační analýza, Hygrotermální podmínky, Vnitřní kvalita vzduchu, Teplota vnitřního vzduchu; Vnitřní prostředí; Relativní vlhkost; Testování statistických hypotéz

Keywords in English

Correlation analysis; Hygrothermal conditionsIndoor; air quality; Indoor air temperature; Indoor environment; Relative humidity; Statistical hypothesis testing

Tags

ENS, RIV18, SCOPUS
Změněno: 4/1/2019 11:33, Mgr. Eva Hynešová

Abstract

ORIG CZ

V originále

Synergic effect of the individual components of the indoor environment is considered to be a significant determinant of the quality of the indoor environment. The quality of the indoor environment affects not only the user's comfort but also the health of the users of the buildings. The main objective of the paper is to confirm or exclude a statistically significant impact of hygro-thermal conditions on the indoor air quality (IAQ). Hygrothermal conditions and indoor air quality are the essential components of the indoor environment. The indoor air temperature [°C], the relative humidity [%] and the indoor air quality are monitored in the apartment of the prefabricated residential building (Ostrava, Czech Republic) during several months. The measuring MEMS MOS gas sensor AS-MLV-P2 contains a metal oxide semiconductor based gas sensor detecting differences the concentration of harmful substances such as alcohols, aldehydes, ketones, organic acids, amines, and aliphatic and aromatic hydrocarbons. The measured gas concentration is calculated with an algorithm into a CO(2) equivalent [ppm]. The observed values are subjected to correlation analysis.

In Czech

Synergický efekt jednotlivých složek vnitřního prostředí je považován za významný determinant kvality vnitřního prostředí. Kvalita vnitřního prostředí ovlivňuje nejen pohodlí uživatele, ale také zdraví uživatelů budov. Hlavním cílem práce je potvrdit nebo vyloučit statisticky významný dopad hygrotermických podmínek na kvalitu vnitřního vzduchu (IAQ). Hygrotermální podmínky a kvalita vnitřního vzduchu jsou základními složkami vnitřního prostředí. Teplota vnitřního vzduchu [° C], relativní vlhkost [%] a kvalita vnitřního vzduchu jsou monitorovány v bytě v prefabrikované obytné budově (Ostrava, Česká republika) během několika měsíců. Měřící senzor MEMS MOS AS-MLV-P2 obsahuje plynový senzor založený na polovodičovém kovovém oxidu, který detekuje rozdíly v koncentraci škodlivých látek, jako jsou alkoholy, aldehydy, ketony, organické kyseliny, aminy a alifatické a aromatické uhlovodíky. Naměřená koncentrace plynu se vypočítá algoritmem na ekvivalent CO2 [ppm]. Pozorované hodnoty jsou podrobeny korelační analýze.
Displayed: 25/11/2024 07:00