D 2017

Influence of the frontal joint of the bitumen sheet on the final strength of the joint

PLACHÝ, Jan; Jana VYSOKÁ and Radek VEJMELKA

Basic information

Original name

Influence of the frontal joint of the bitumen sheet on the final strength of the joint

Name in Czech

Vliv typu úpravy povrchu čelního spoje asfaltového pásu na výslednou pevnost spoje

Authors

PLACHÝ, Jan; Jana VYSOKÁ and Radek VEJMELKA

Edition

1. vyd. France, 9th International Scientific Conference BUILDING DEFECTS 2017, p. nestránkováno, 5 pp. 2017

Publisher

MATEC Web of Conferences

Other information

Language

English

Type of outcome

Proceedings paper

Field of Study

20102 Construction engineering, Municipal and structural engineering

Country of publisher

France

Confidentiality degree

is not subject to a state or trade secret

Publication form

printed version "print"

Marked to be transferred to RIV

Yes

RIV identification code

RIV/75081431:_____/17:00001263

Organization unit

Institute of Technology and Business in České Budějovice

ISBN

978-2-7598-9032-3

Keywords (in Czech)

Asfaltové hydroizolační pásy; asfalt; asfaltová hmota; krycí hmota; nosná vložka; rozměrová stálost

Keywords in English

reinforced bitumen sheets for waterproofing; bitumen; mass of bitumen; coating; carrier; dimensional stability

Tags

Changed: 4/7/2018 09:10, Mgr. Blanka Mikšíková

Abstract

In the original language

This article focuses on the frequently discussed topic how to make the frontal joints of bitumen sheets with coarse-grained surface coating. Bitumen sheets have a spill in the place of these joints. Insufficient strength of the frontal joint is one of the possible faults in waterproofing using bitumen sheets. The paper compares different ways of performing these joints in terms of force stress based on surface treatment. Surface treatment is possible by immersing the sprinkle, scraping it into the bitumen sheet mass, or simply heating the surface and leaving it unpainted.

In Czech

Tento článek se věnuje často diskutovanému tématu a to jakým způsobem provádět čelní spoje u asfaltových pásů s povrchovou úpravou hrubozrnným posypem. Asfaltové pásy totiž v místě těchto spojů mají posyp. Nedostatečná pevnost čelního spoje je jednou z možných poruch hydroizolace pomocí asfaltových pásů. Příspěvek porovnává z hlediska silového namáhání různé způsoby provedení těchto spojů na základě úpravy povrchu. Úprava povrchu je možná pomocí ponoření posypu, zatřením posypu do hmoty asfaltového pásu anebo je možné povrch pouze nahřát a nechat bez úpravy.