2017
Insufficient dimensional stability of bitumen sheets as a source of flat roof defects
PLACHÝ, Jan; Jana VYSOKÁ and Radek VEJMELKABasic information
Original name
Insufficient dimensional stability of bitumen sheets as a source of flat roof defects
Name in Czech
Nedostatečná rozměrová stálost asfaltových pásů jako zdroj defektů plochých střech
Authors
PLACHÝ, Jan; Jana VYSOKÁ and Radek VEJMELKA
Edition
1. vyd. France, 9th International Scientific Conference BUILDING DEFECTS 2017, p. nestránkováno, 6 pp. 2017
Publisher
MATEC Web of Conferences
Other information
Language
English
Type of outcome
Proceedings paper
Field of Study
20102 Construction engineering, Municipal and structural engineering
Country of publisher
France
Confidentiality degree
is not subject to a state or trade secret
Publication form
printed version "print"
Marked to be transferred to RIV
Yes
RIV identification code
RIV/75081431:_____/17:00001262
Organization unit
Institute of Technology and Business in České Budějovice
ISBN
978-2-7598-9032-3
Keywords (in Czech)
Asfaltové hydroizolační pásy; asfalt; asfaltová hmota; krycí hmota; nosná vložka; rozměrová stálost
Keywords in English
reinforced bitumen sheets for waterproofing; bitumen; mass of bitumen; coating; carrier; dimensional stability
Changed: 4/7/2018 08:39, Mgr. Blanka Mikšíková
In the original language
One of the frequent sources of flat roof faults is failure of the top layer of a multilayer bitumen sheet system in cross-connections. One of the possible causes of this disorder is failure to observe technological discipline. The paper deals with how the full melting of the bitumen sheet influences its possible shrinkage during the roof exposure. Bitumen sheets with a polyester carrier which is not reinforced with fiberglass fibers are burdened with shrinkage effect. The preload is introduced into these belts during production. The aim is to show how is the effect on loosening the preload in the carrier layer with full-scale smelting during the realization of the waterproofing layer. The preload loosening experiment, expressed by the dimensional stability test according to ČSN EN 1107, was performed in a laboratory on two bitumen sheets.
In Czech
Jeden z častých zdrojů poruch na plochých střechách je porušení vrchní vrstvy vícevrstvého systému z asfaltových pásů v příčných spojích. Jednou z možných příčin této poruchy je nedodržení technologické kázně. Příspěvek se zabývá jak ovlivňuje plnoplošné natavení asfaltového pásu jeho případné smrštění během expozice na střeše. Efektem smrštění jsou zatíženy asfaltové pásy s nosnonou vložkou z polyesteru, která není vyztužena vlákny ze skelné tkaniny. Předpětí je do těchto pásů vneseno již během výroby. Cílem je ukázat, jaký vliv na uvolnění předpětí v nosné vložce má plnoplošné natavení během realizace hydroizolačního souvrství. Experiment s uvolněním předpětí, vyjádřený pomocí zkoušky rozměrová stálost dle ČSn EN 1107, byl prováděn v laboratoři na dvou asfaltových pásech.