D 2017

Hygrothermal Analysis of Indoor Environment of Residential Prefabricated Buildings

KRAUS, Michal

Basic information

Original name

Hygrothermal Analysis of Indoor Environment of Residential Prefabricated Buildings

Name in Czech

Tepelně-vlhkostní analýza vnitřního prostředí prefabrikovaných panelových budov

Authors

KRAUS, Michal (203 Czech Republic, guarantor, belonging to the institution)

Edition

1. vyd. Spojené království, IOP Conference Series: Materials Science and Engineering, Volume 245, Issue 4 (World Multidisciplinary Civil Engineering-Architecture-Urban Planning Symposium, p. 042071-42077, 2017

Publisher

Institute of Physics Publishing

Other information

Language

English

Type of outcome

Stať ve sborníku

Field of Study

20101 Civil engineering

Country of publisher

United Kingdom of Great Britain and Northern Ireland

Confidentiality degree

není předmětem státního či obchodního tajemství

Publication form

electronic version available online

References:

Open Access

RIV identification code

RIV/75081431:_____/17:00001164

Organization unit

Institute of Technology and Business in České Budějovice

ISSN

DOI

http://dx.doi.org/10.1088/1757-899X/245/4/042071

Keywords (in Czech)

Bytový dům; budovy; prefabrikované konstrukce; tepelný komfort; tepelně-vlhkostní analýza; vniřní prostředí; teoplota vzduchu; vytápěníBytový dům; budovy; prefabrikované konsrukce; tepelný komfort; tepelně-vlhkostní analýza; vnitřní prostředí; teplota vzduchu; vytápění

Keywords in English

Apartment houses; buildings; prefabricated construction; thermal comfort; hygro-thermal analysis; indoor environment; indoor air temperature; heating

Tags

BDP, JN, RIV17, SCOPUS

Tags

International impact, Reviewed
Změněno: 20/4/2018 11:18, Mgr. Blanka Mikšíková

Abstract

ORIG CZ

V originále

Recent studies show that the relative humidity and the indoor air temperature constitute an important determinant of the quality of indoor air. Hygrothermal microclimate has a significant impact on occupant’s health and their comfort. The study presents the results of experimental measurement of indoor air temperature and relative humidity in selected apartment in prefabricated panel house situated in Ostrava, Czechia. The contribution describes and analysis the relation between indoor air temperature [°C] and relative humidity [%] in this apartment. The experimental object is selected with respect to the housing stock in the Czech Republic. A third of the housing stock in the Czech Republic is composed of prefabricated panel houses. Regeneration and revitalization of these buildings were in the focus of interest during recent years. Building modifications, such as thermal insulation of building envelope or window replacement, lead to a significantly higher level of airtightness of these objects. Humidity and indoor air temperature are measured in 10-minute cycles for two periods. The values of temperature and humidity are measured for the non-heating and the heating season. The length of each experimental period is 30 days. The mean value of indoor air temperature is 22.21 °C and average relative humidity is 45.87% in the non-heating period. The values of 22.62 °C and 35.20% represent average values for the heating period. A slight increase of the average temperature of the indoor environment (+1.85%) is observed. The decrease of the relative humidity is evident at first glance. The relative humidity of the internal environment is approximately 10% lower in the heating period. Long-term decline of relative humidity below 30% brings many problems. It is necessary to take measures to increase of relative humidity in residential prefabricated building. The aquarium appears to be ineffective. The solution may be forced artificial ventilation or humidifiers.

In Czech

Současné studie ukazují, že relativní vlhkost a teplota vnitřního vzduchu jsou důležitými faktory determinanty kvality vnitřního prostředí. Tepelně-vlhkostní mikroklima mý významný dopad na zdraví uživatelů budov a jejich komfort. Studie prezentuje výsledky experimentálního měření teploty vnitřního vzduchu a relativní vlhkosti ve vybraném bytě prefabrikovaného panelového domu (Ostrava, Česká republika). Příspěvek se zabývá analýzou teploty vnitřního vzduchu [°C] a relativní vlhkosti [%] v posuzované místnosti. Objekt experimentálního měření byl vybrán v závislosti na reprezentaci bytového fondu ČR. Třetina bytového fondu České republiky je tvořen byty v prefabrikovaných panelových domech. Regenerace a revitalizace těchto budov je v posledních letech předmětem zájmu. Stavební úpravy jako je dodatečné zateplení nebo výměna oken vedou k výrazně nižší úrovni průvzdušnosti obvodového pláště těchto budov. Vlhkost a teplota vnitřního vzduchu jsou měřeny v 10-minutových cyklech po dobu dvou období. Teplota a vlhkost je měřena v období vytápění a v sezóně bez vytápění. Délka každého měřeného experimentálního období je 30 dní. Průměrná teplota je 22,21 °C a průměrná vlhkost 45,87 % v období bez vytápění. V otopné sezóně je průměrná teplota 22,62 °C a vlhkost 35,20 %. Mírný nárůst průměrné teploty (1,85 °C) je pozorován v období vytápění. Relativní vlhkost v otopné sezóně je menší cca o 10 %. Dlouhodobý pokles relativní vlhkost pod 30 % přináší celou řadu problémů. Je nezbytné přijmout opatření, která povedou ke zvýšení relativní vlhkosti vnitřního prostředí. Akvárium se i přes značný odpar jeví jako neúčinné. Řešením může být dodatečná instalace nuceného větrání nebo zvlhčovače vzduchu.
Displayed: 18/11/2024 15:22