Airtightness analysis relation to the construction system and material solution

KRAUS, Michal

Basic information

Original name

Airtightness analysis relation to the construction system and material solution

Name in Czech

Analýza vzduchotěsnosti s ohledem na konstrukční systém a materiálové řešení

Authors

KRAUS, Michal (203 Czech Republic, guarantor, belonging to the institution)

Edition

1. vyd. Sofia (Bulharsko), 17th International Multidisciplinary Scientific GeoConference, SGEM 2017: Volume 17 Nano, Bio and Green and Space - Technologies for a Sustainable Future, Issue 62, p. 481-486, 6 pp. 2017

Publisher

STEF92 TECHNOLOGY LTD

Other information

Language

English

Type of outcome

Stať ve sborníku

Field of Study

20101 Civil engineering

Country of publisher

Bulgaria

Confidentiality degree

není předmětem státního či obchodního tajemství

Publication form

printed version "print"

RIV identification code

RIV/75081431:_____/17:00001161

Organization unit

Institute of Technology and Business in České Budějovice

ISBN

978-619-7408-10-2

ISSN

DOI

http://dx.doi.org/10.5593/sgem2017/62/S26.061

Keywords (in Czech)

Vzduchotěsnost; analýza; konstrukční systém, stavební materiály; energetická náročnost budov; neprůvzdušnost

Keywords in English

Airtightness; analysis; construction system; building material; energy efficient building; air permeability

Tags

ATL_1, RIV17, SCOPUS

Tags

International impact, Reviewed
Změněno: 20/4/2018 11:14, Mgr. Blanka Mikšíková

Abstract

ORIG CZ

V originále

In connection with the requirements of energy saving and reducing greenhouse gas emissions, the current construction is characterized by high levels of airtightness of the building envelope. On the other hand, high levels of airtightness can be the cause of poor indoor air quality due to inadequate ventilation. Energy savings and ensuring the quality of the indoor environment are two confronting requirements of the current construction. The airtightness can be defined as a resistance of the construction to infiltration air. The building envelope should be airtight in order to prevent uncontrolled leak air. Air tightness of building envelopes is usually expressed in terms of total air exchange rate at pressure difference 50 Pa. This paper analyzes the airtightness of energy efficient buildings in terms of the construction system and building materials. The analysis are investigated both vertical and horizontal constructions. The basic data set consists of energy-efficient buildings built in the years 2004-2014 in the Czech Republic

In Czech

V souvislosti s požadavky na úsporu energie a snížení produkce emisí skleníkových plynů se stávající výstavba vyznačuje vysokou vzduchotěsností obvodového pláště budov. Vysoká míra vzduchotěsnosti obálky budov může být příčinou špatné kvality vnitřního prostředí v důsledku nedostatečné výměny vzduchu. Úspora energie a hygienické požadavky jsou v konfrontaci současné výstavby. Vzduchotěsnost lze definovat jako odolnost konstrukce proti infiltraci. Obálka budovy by měla být vzduchotěsná a zabránit tak nekontrolovatelné výměně vzduchu. Vzduchotěsnost se běžně vyjadřuje v hodnotách celkové intenzity výměny vzduchu při tlakovém rozdílu 50 Pa. Příspěvek analyzuje vzduchotěsnost obálky energeticky úsporných budov z hlediska konstrukčního systému a použitých stavebních materiálů. Analýza se věnuje horizontálním i vertikálním konstrukcím. Základový soubor je tvořen energeticky úpornými budovami postavených v letech 2004 – 2014 v České republice.