KRAUS, Michal. Airtightness analysis relation to the construction system and material solution. In 17th International Multidisciplinary Scientific GeoConference, SGEM 2017: Volume 17 Nano, Bio and Green and Space - Technologies for a Sustainable Future, Issue 62. 1. vyd. Sofia (Bulharsko): STEF92 TECHNOLOGY LTD, 2017, p. 481-486. ISBN 978-619-7408-10-2. Available from: https://dx.doi.org/10.5593/sgem2017/62/S26.061.
Other formats:   BibTeX LaTeX RIS
Basic information
Original name Airtightness analysis relation to the construction system and material solution
Name in Czech Analýza vzduchotěsnosti s ohledem na konstrukční systém a materiálové řešení
Authors KRAUS, Michal (203 Czech Republic, guarantor, belonging to the institution).
Edition 1. vyd. Sofia (Bulharsko), 17th International Multidisciplinary Scientific GeoConference, SGEM 2017: Volume 17 Nano, Bio and Green and Space - Technologies for a Sustainable Future, Issue 62, p. 481-486, 6 pp. 2017.
Publisher STEF92 TECHNOLOGY LTD
Other information
Original language English
Type of outcome Proceedings paper
Field of Study 20101 Civil engineering
Country of publisher Bulgaria
Confidentiality degree is not subject to a state or trade secret
Publication form printed version "print"
RIV identification code RIV/75081431:_____/17:00001161
Organization unit Institute of Technology and Business in České Budějovice
ISBN 978-619-7408-10-2
ISSN 1314-2704
Doi http://dx.doi.org/10.5593/sgem2017/62/S26.061
Keywords (in Czech) Vzduchotěsnost; analýza; konstrukční systém, stavební materiály; energetická náročnost budov; neprůvzdušnost
Keywords in English Airtightness; analysis; construction system; building material; energy efficient building; air permeability
Tags ATL_1, RIV17, SCOPUS
Tags International impact, Reviewed
Changed by Changed by: Mgr. Blanka Mikšíková, učo 22534. Changed: 20/4/2018 11:14.
Abstract
In connection with the requirements of energy saving and reducing greenhouse gas emissions, the current construction is characterized by high levels of airtightness of the building envelope. On the other hand, high levels of airtightness can be the cause of poor indoor air quality due to inadequate ventilation. Energy savings and ensuring the quality of the indoor environment are two confronting requirements of the current construction. The airtightness can be defined as a resistance of the construction to infiltration air. The building envelope should be airtight in order to prevent uncontrolled leak air. Air tightness of building envelopes is usually expressed in terms of total air exchange rate at pressure difference 50 Pa. This paper analyzes the airtightness of energy efficient buildings in terms of the construction system and building materials. The analysis are investigated both vertical and horizontal constructions. The basic data set consists of energy-efficient buildings built in the years 2004-2014 in the Czech Republic
Abstract (in Czech)
V souvislosti s požadavky na úsporu energie a snížení produkce emisí skleníkových plynů se stávající výstavba vyznačuje vysokou vzduchotěsností obvodového pláště budov. Vysoká míra vzduchotěsnosti obálky budov může být příčinou špatné kvality vnitřního prostředí v důsledku nedostatečné výměny vzduchu. Úspora energie a hygienické požadavky jsou v konfrontaci současné výstavby. Vzduchotěsnost lze definovat jako odolnost konstrukce proti infiltraci. Obálka budovy by měla být vzduchotěsná a zabránit tak nekontrolovatelné výměně vzduchu. Vzduchotěsnost se běžně vyjadřuje v hodnotách celkové intenzity výměny vzduchu při tlakovém rozdílu 50 Pa. Příspěvek analyzuje vzduchotěsnost obálky energeticky úsporných budov z hlediska konstrukčního systému a použitých stavebních materiálů. Analýza se věnuje horizontálním i vertikálním konstrukcím. Základový soubor je tvořen energeticky úpornými budovami postavených v letech 2004 – 2014 v České republice.
PrintDisplayed: 1/6/2024 19:43