Indoor Air Quality Analysis of Residental Buildings
KRAUS, Michal and Ingrid JUHÁSOVÁ ŠENITKOVÁBasic information
Original name
Indoor Air Quality Analysis of Residental Buildings
Name in Czech
Analýza kvality vnitřního prostředí v obytných budovách
Authors
KRAUS, Michal (203 Czech Republic, guarantor, belonging to the institution) and Ingrid JUHÁSOVÁ ŠENITKOVÁ (703 Slovakia, belonging to the institution)
Edition
1. vyd. Sofia (Bulharsko), 17th International Multidisciplinary Scientific GeoConference, SGEM 2017: Volume 17 Nano, Bio and Green and Space - Technologies for a Sustainable Future, Issue 62, p. 651-657, 7 pp. 2017
Publisher
STEF92 TECHNOLOGY LTD
Other information
Language
English
Type of outcome
Stať ve sborníku
Field of Study
20101 Civil engineering
Country of publisher
Bulgaria
Confidentiality degree
není předmětem státního či obchodního tajemství
Publication form
printed version "print"
RIV identification code
RIV/75081431:_____/17:00001114
Organization unit
Institute of Technology and Business in České Budějovice
ISBN
978-619-7408-13-3
ISSN
Keywords (in Czech)
kvalita vnitřního prostředí, těkavé organické látky; vnitřní prostředí; syndrom nezdravých budov
Keywords in English
indoor air quality; volatile organic; indoor environment; sick building syndrome
Tags
International impact, Reviewed
Změněno: 20/4/2018 11:18, Mgr. Blanka Mikšíková
V originále
The contribution deals with the indoor air quality (IAQ) in residential prefabricated panel houses, which represent a significant proportion of the housing stock in the Czech Republic. Ensuring the health and comfort of users is a phenomenon of present time in accordance with the principles of sustainable development. Almost two thirds of building occupants suffer from the symptoms of Sick Building Syndrome (SBS). Concentration of pollutants in indoor environments increases due to increasing of airtightness of the building envelope and due to insufficient ventilation. The main source of contaminants is the human and its every-day activities such as breath, skin respiration, flatus and using cosmetics or perfumes. Building materials, furniture and equipment of building are also a source of harmful emissions. Experimental measurements were carried out in autumn/winter 2016 in characteristic apartment of prefabricated panel house (Ostrava, Czech Republic). The high-performance AS-MLV-P2 MEMS (Micro Electro Mechanical System) gas sensor was used for VOC detection. The obtained levels of volatile organic compounds are expressed in the values of CO2 equivalent [ppm]. The obtained results are described and analysed in this paper.
In Czech
Příspěvek se zabývá kvalitou vnitřního prostředí (IAQ) v prefabrikovaných panelových budovách, které reprezentují významný podíl bytové výstavby v České republice. Zajištění zdraví a komfortu uživatelů je současným fenoménem v kontextu trvale udržitelného rozvoje. Téměř 2/3 uživatelů budov trpí Syndromem nezdravých budov (SBS). Koncentrace polutantů ve vnitřním prostředí (IE) rostou díky zvyšující se vzduchotěsnosti obálky budovy a také díky nedostatečnému větrání. Hlavním zdrojem polutantů je člověk a jeho každodenní aktivity jako je dýchání, pocení a používání kosmetických prostředků nebo parfémů. Stavební materiály, nábytek a další vybavení budov jsou taktéž významným zdrojem škodlivých emisí. Experimentální měření bylo provedeno v období podzim – zima 2016 v charakteristickém bytě panelového domu v Ostravě (Česká republika). Vysoce výkonný plynový senzor (AS-MLV-P2 MEMS) byl použit pro detekci VOC. Získané hodnoty jsou vyjádřené pomocí ekvivalentu CO2 [PPM]. Získané výsledky jsou popsány a analyzovány v samotném příspěvku.