D 2017

Indoor Air Quality Analysis of Residental Buildings

KRAUS, Michal and Ingrid JUHÁSOVÁ ŠENITKOVÁ

Basic information

Original name

Indoor Air Quality Analysis of Residental Buildings

Name in Czech

Analýza kvality vnitřního prostředí v obytných budovách

Authors

KRAUS, Michal (203 Czech Republic, guarantor, belonging to the institution) and Ingrid JUHÁSOVÁ ŠENITKOVÁ (703 Slovakia, belonging to the institution)

Edition

1. vyd. Sofia (Bulharsko), 17th International Multidisciplinary Scientific GeoConference, SGEM 2017: Volume 17 Nano, Bio and Green and Space - Technologies for a Sustainable Future, Issue 62, p. 651-657, 7 pp. 2017

Publisher

STEF92 TECHNOLOGY LTD

Other information

Language

English

Type of outcome

Stať ve sborníku

Field of Study

20101 Civil engineering

Country of publisher

Bulgaria

Confidentiality degree

není předmětem státního či obchodního tajemství

Publication form

printed version "print"

RIV identification code

RIV/75081431:_____/17:00001114

Organization unit

Institute of Technology and Business in České Budějovice

ISBN

978-619-7408-13-3

ISSN

DOI

http://dx.doi.org/10.5593/sgem2017/62/S27.083

Keywords (in Czech)

kvalita vnitřního prostředí, těkavé organické látky; vnitřní prostředí; syndrom nezdravých budov

Keywords in English

indoor air quality; volatile organic; indoor environment; sick building syndrome

Tags

BDP, RIV17, SCOPUS

Tags

International impact, Reviewed
Změněno: 20/4/2018 11:18, Mgr. Blanka Mikšíková

Abstract

ORIG CZ

V originále

The contribution deals with the indoor air quality (IAQ) in residential prefabricated panel houses, which represent a significant proportion of the housing stock in the Czech Republic. Ensuring the health and comfort of users is a phenomenon of present time in accordance with the principles of sustainable development. Almost two thirds of building occupants suffer from the symptoms of Sick Building Syndrome (SBS). Concentration of pollutants in indoor environments increases due to increasing of airtightness of the building envelope and due to insufficient ventilation. The main source of contaminants is the human and its every-day activities such as breath, skin respiration, flatus and using cosmetics or perfumes. Building materials, furniture and equipment of building are also a source of harmful emissions. Experimental measurements were carried out in autumn/winter 2016 in characteristic apartment of prefabricated panel house (Ostrava, Czech Republic). The high-performance AS-MLV-P2 MEMS (Micro Electro Mechanical System) gas sensor was used for VOC detection. The obtained levels of volatile organic compounds are expressed in the values of CO2 equivalent [ppm]. The obtained results are described and analysed in this paper.

In Czech

Příspěvek se zabývá kvalitou vnitřního prostředí (IAQ) v prefabrikovaných panelových budovách, které reprezentují významný podíl bytové výstavby v České republice. Zajištění zdraví a komfortu uživatelů je současným fenoménem v kontextu trvale udržitelného rozvoje. Téměř 2/3 uživatelů budov trpí Syndromem nezdravých budov (SBS). Koncentrace polutantů ve vnitřním prostředí (IE) rostou díky zvyšující se vzduchotěsnosti obálky budovy a také díky nedostatečnému větrání. Hlavním zdrojem polutantů je člověk a jeho každodenní aktivity jako je dýchání, pocení a používání kosmetických prostředků nebo parfémů. Stavební materiály, nábytek a další vybavení budov jsou taktéž významným zdrojem škodlivých emisí. Experimentální měření bylo provedeno v období podzim – zima 2016 v charakteristickém bytě panelového domu v Ostravě (Česká republika). Vysoce výkonný plynový senzor (AS-MLV-P2 MEMS) byl použit pro detekci VOC. Získané hodnoty jsou vyjádřené pomocí ekvivalentu CO2 [PPM]. Získané výsledky jsou popsány a analyzovány v samotném příspěvku.
Displayed: 30/12/2024 23:22