Další formáty:
BibTeX
LaTeX
RIS
@inproceedings{39823, author = {Kraus, Michal and Juhásová Šenitková, Ingrid}, address = {Sofia (Bulharsko)}, booktitle = {17th International Multidisciplinary Scientific GeoConference, SGEM 2017: Volume 17 Nano, Bio and Green and Space - Technologies for a Sustainable Future, Issue 62}, doi = {http://dx.doi.org/10.5593/sgem2017/62/S27.083}, edition = {1. vyd.}, keywords = {indoor air quality; volatile organic; indoor environment; sick building syndrome}, howpublished = {tištěná verze "print"}, language = {eng}, location = {Sofia (Bulharsko)}, isbn = {978-619-7408-13-3}, pages = {651-657}, publisher = {STEF92 TECHNOLOGY LTD}, title = {Indoor Air Quality Analysis of Residental Buildings}, year = {2017} }
TY - JOUR ID - 39823 AU - Kraus, Michal - Juhásová Šenitková, Ingrid PY - 2017 TI - Indoor Air Quality Analysis of Residental Buildings PB - STEF92 TECHNOLOGY LTD CY - Sofia (Bulharsko) SN - 9786197408133 KW - indoor air quality KW - volatile organic KW - indoor environment KW - sick building syndrome N2 - The contribution deals with the indoor air quality (IAQ) in residential prefabricated panel houses, which represent a significant proportion of the housing stock in the Czech Republic. Ensuring the health and comfort of users is a phenomenon of present time in accordance with the principles of sustainable development. Almost two thirds of building occupants suffer from the symptoms of Sick Building Syndrome (SBS). Concentration of pollutants in indoor environments increases due to increasing of airtightness of the building envelope and due to insufficient ventilation. The main source of contaminants is the human and its every-day activities such as breath, skin respiration, flatus and using cosmetics or perfumes. Building materials, furniture and equipment of building are also a source of harmful emissions. Experimental measurements were carried out in autumn/winter 2016 in characteristic apartment of prefabricated panel house (Ostrava, Czech Republic). The high-performance AS-MLV-P2 MEMS (Micro Electro Mechanical System) gas sensor was used for VOC detection. The obtained levels of volatile organic compounds are expressed in the values of CO2 equivalent [ppm]. The obtained results are described and analysed in this paper. ER -
KRAUS, Michal a Ingrid JUHÁSOVÁ ŠENITKOVÁ. Indoor Air Quality Analysis of Residental Buildings. In \textit{17th International Multidisciplinary Scientific GeoConference, SGEM 2017: Volume 17 Nano, Bio and Green and Space - Technologies for a Sustainable Future, Issue 62}. 1. vyd. Sofia (Bulharsko): STEF92 TECHNOLOGY LTD, 2017, s.~651-657. ISBN~978-619-7408-13-3. Dostupné z: https://dx.doi.org/10.5593/sgem2017/62/S27.083.
|