MUSÍLEK, Josef and Luboš PODOLKA. Calculation and reliability of timber structure bolt connection subjected to double unequal shears with thick plates as outer members. Online. In I. Juhásová Šenitková, T. Vondráčková, M. Kraus, J. Plachý. MATEC Web of Conferences 93 (2017): 8th International Scientific Conference Building Defects (Building Defects 2016). České Budějovice: Vysoká škola technická a ekonomická v Českých Budějovicích, 2016, p. 61-65. ISBN 978-80-7468-109-7. |
Other formats:
BibTeX
LaTeX
RIS
@inproceedings{35923, author = {Musílek, Josef and Podolka, Luboš}, address = {České Budějovice}, booktitle = {MATEC Web of Conferences 93 (2017): 8th International Scientific Conference Building Defects (Building Defects 2016)}, editor = {I. Juhásová Šenitková, T. Vondráčková, M. Kraus, J. Plachý}, keywords = {timber structures; steel; bolt connections; unequal double shear}, howpublished = {elektronická verze "online"}, language = {eng}, location = {České Budějovice}, isbn = {978-80-7468-109-7}, pages = {61-65}, publisher = {Vysoká škola technická a ekonomická v Českých Budějovicích}, title = {Calculation and reliability of timber structure bolt connection subjected to double unequal shears with thick plates as outer members}, year = {2016} }
TY - JOUR ID - 35923 AU - Musílek, Josef - Podolka, Luboš PY - 2016 TI - Calculation and reliability of timber structure bolt connection subjected to double unequal shears with thick plates as outer members PB - Vysoká škola technická a ekonomická v Českých Budějovicích CY - České Budějovice SN - 9788074681097 KW - timber structures KW - steel KW - bolt connections KW - unequal double shear N2 - The paper shows the calculation and reliability assessment of bolted connections subjected to unequal double shear with thick plates as outer members and inner timber member. This situation can occur very often during the designing of the timber structure bolt connection. Bolted connections subjected to unequal double shear are not described in present European standards where there is described only calculation and reliability of timber structure bolt connection subjected to double equal shears. So structure engineers have no rules which help them during a designing process when they are confronted with this case. The concrete example for the case of unequal shears is calculated and explained. ER -
MUSÍLEK, Josef and Luboš PODOLKA. Calculation and reliability of timber structure bolt connection subjected to double unequal shears with thick plates as outer members. Online. In I. Juhásová Šenitková, T. Vondráčková, M. Kraus, J. Plachý. \textit{MATEC Web of Conferences 93 (2017): 8th International Scientific Conference Building Defects (Building Defects 2016)}. České Budějovice: Vysoká škola technická a ekonomická v Českých Budějovicích, 2016, p.~61-65. ISBN~978-80-7468-109-7.
|