D 2016

Pairwaise Comparision of Determinants of Building Airtightness

KRAUS, Michal

Basic information

Original name

Pairwaise Comparision of Determinants of Building Airtightness

Name in Czech

Párové srovnání determinantů vzduchotěsnosti budov

Authors

KRAUS, Michal (203 Czech Republic, guarantor, belonging to the institution)

Edition

1. vyd. Sofia (Bulharsko), 16th International Multidisciplinary Scientific GeoConference SGEM 2016, p. 577-584, 8 pp. 2016

Publisher

STEF92 TECHNOLOGY LTD

Other information

Language

English

Type of outcome

Proceedings paper

Field of Study

20101 Civil engineering

Country of publisher

Bulgaria

Confidentiality degree

is not subject to a state or trade secret

Publication form

printed version "print"

References:

RIV identification code

RIV/75081431:_____/16:00001021

Organization unit

Institute of Technology and Business in České Budějovice

ISBN

978-619-7105-79-7

ISSN

Keywords (in Czech)

vzduchotěsnost; průvzdušnost; obálka budovy; párové srovnání; fullerův trojúhelník

Keywords in English

airtightness; air permeability; building envelope; pairwise comparison; fuller’s triangle

Tags

Tags

International impact, Reviewed
Changed: 20/4/2018 08:08, Mgr. Blanka Mikšíková

Abstract

V originále

Contemporary tendencies of building constructions are mainly concentrate on saving energy and reducing greenhouse gas emissions in accordance with the rules of sustainable development. The significance of the airtightness of building envelope is demonstrably non-negligible for energy-efficient constructions. Uncontrolled flow of air through the building envelopes negatively influences the energy balance of the building. In some cases, it reduces the life of the structure and increases the risk of defects, such as condensation of water vapor and the occurrence of mold. High quality and airtight building envelope can reduce the demand for heating by up to 10 %. The paper deals with the determination of significant factors of building airtightness using the method of pairwise comparison (Fuller’s triangle). The method of Fuller’s triangle is based on select preferred factor of a pair of factors. The newly acquired results are compared with previously obtained information based on statistical methods (statistical Test of independence) and quality management tools (Cause and Effect Diagram and brainstorming). Implementation of new knowledge into the building practice can significantly affect the quality of envelope already in pre-production phase and design phase.

Files attached

Pairwise_Comparison_of_Determining_Factors_of_Building_Airtightness.pdf
Request the author's version of the file