D 2016

Airtightness as Key Factor of Sick Building Syndrome (SBS)

KRAUS, Michal

Basic information

Original name

Airtightness as Key Factor of Sick Building Syndrome (SBS)

Name in Czech

Vzduchotěsnost jako klíčový faktor Syndromu nezdravých budov (SBS)

Authors

KRAUS, Michal (203 Czech Republic, guarantor, belonging to the institution)

Edition

1. vyd. Sofia (Bulharsko), 16th International Multidisciplinary Scientific GeoConference, SGEM 2016: Book 6 Nano, Bio and Green - Technologies for a Sustainable Future, Volume II, p. 439-445, 7 pp. 2016

Publisher

International Multidisciplinary Scientific Geoconference

Other information

Language

English

Type of outcome

Stať ve sborníku

Field of Study

20101 Civil engineering

Country of publisher

Bulgaria

Confidentiality degree

není předmětem státního či obchodního tajemství

Publication form

printed version "print"

RIV identification code

RIV/75081431:_____/16:00000702

Organization unit

Institute of Technology and Business in České Budějovice

ISBN

978-619-7105-69-8

ISSN

DOI

http://dx.doi.org/10.5593/sgem2016B62

Keywords (in Czech)

vzduchotěsnost; energeticky-efektivní budova; syndrom nezdravých budov; SBS, kvalita vnitřního prostředí

Keywords in English

airtightness; energy - efficient building; sick building syndrome; SBS; indoor air quality

Tags

IF, RIV16

Tags

International impact, Reviewed
Změněno: 22/8/2016 13:12, Ing. Michal Kraus, Ph.D.

Abstract

ORIG CZ

V originále

The paper deals with the indoor air quality in term or ever-increasing airtightness of building envelopes. In accordance with sustainable development, contemporary construction of buildings is focused on energy-efficient and green architecture. The main principle of the solution of these buildings is to achieve energy savings and reducing the production of greenhouse gas emissions. Cracks and gaps in the building envelope are places of uncontrolled air leakage. An uncontrolled escape air through building envelope contributes to the higher heat losses of the building. Energy-efficient buildings are characterized by high airtightness of the building envelope. Inadequate air change rate (1/h) may have significant impact on the indoor air quality. Ensuring fresh clean air together with temperature, relative humidity are key factors creating healthy indoor environments. Otherwise, there is an accumulation of concentrations of pollutants (volatile organic compounds) or microbes with negative impact on occupant’s comfort and their health.

In Czech

Příspěvek se zabývá kvalitou vnitřního prostředí v kontextu stále se zvyšující vzduchotěsnosti obálky budovy. V souladu s trvale udržitelným rozvojem, současná výstavba se orientuje na energeticky-efektivní a zelenou architekturu. Hlavním principem je dosáhnout značných úspor energie a snížení produkce emisí skleníkových plynů. Trhliny a netěsnosti v obvodovém plášti jsou místa nekontrolovatelného úniku vzduchu. Nekontrolovatelný únik prokazatelně přispívá ke zvýšeným tepelným ztrátám budovy. Energeticky-efektivní budovy se vyznačují vysokou vzduchotěsností obálky budovy. Nedostatečná výměna vzduchu (1/h) může mít významný dopad na kvalitu vnitřního prostředí. Zajištění čerstvého čistého vzduchu spolu s teplotou, relativní vlhkostí patří mezi klíčové faktory zdravého vnitřního prostředí. V opačném případě dochází ke kumulaci koncentrací znečišťujících látek (těkavé organické sloučeniny) a mikrobů s negativním dopadem na pohodlí uživatelů budov a jejich zdraví.
Displayed: 18/11/2024 16:25