V originále
The paper deals with sensibility of sandy soils shear strength parameters on the size of spread foundation. Minimal, intermediate and maximal values of shear strength parameters of 5 classes of sandy soil (SW, SP, S-F, SM and SC) introduced in the old Slovak Technical Standard STN 731001 had been used to design model spread foundation, similar with this one, posted by Orr (2005). The foundation has square shape, thickness 0.8m, founded in the depth D = 1.5m. The foundation is loaded by centrically acting vertical permanent load G = 900 kN and variable load Q = 600 kN. Underground water level is at foundation base. The spread foundation was designed by design approaches mentioned in Eurocode 7, Part 1 (DA1-C1; DA1-C2; DA2 and DA3) and also by the old and new Slovak Technical Standard STN 73 1001.
In Czech
Článek pojednává o citlivosti parametrů smykové pevnosti písčitých základových půd při návrhu velikosti plošného základu. Minimální, střední a maximální hodnoty smykové pevnosti parametrů 5 tříd písčité půdy (SW, SP, SF, SM a SC), zavedené v původní normě STN 73 1001 byla použita k návrhu modelu plošného základu, podobného jaký přezentoval, Orr (2005). Základ byl čtvercového tvaru, tloušťky 0,8 m, založen byl v hloubce D = 1,5 m. Základ při zatížení svislou centrickou silou od stálého zatížení hodnotou G = 900 kN a proměnlivého zatížení Q = 600 kN. Hladina podzemní vody byla v základové spáře. Základ byl navržen dle návrhového přístupu uvedeného v Eurokódu 7, část 1 (DA1-C1, DA1-C2, DA2 a DA3), a také dle staré a nové Slovenské technické normy STN 73 1001.