D 2015

Sensibility of Sandy Soils Shear Strength Parameters on a Size of Spread Foundation

NGUYEN, Giang, Terezie VONDRÁČKOVÁ, Marian DRUSA, Luboš KOVALČÍK, Ondrej STOPKA et. al.

Basic information

Original name

Sensibility of Sandy Soils Shear Strength Parameters on a Size of Spread Foundation

Name in Czech

Citlivost smykových parametrů písčitých základových půd na velikost plošného základu

Authors

NGUYEN, Giang (704 Viet Nam), Terezie VONDRÁČKOVÁ (203 Czech Republic, belonging to the institution), Marian DRUSA (703 Slovakia), Luboš KOVALČÍK (703 Slovakia) and Ondrej STOPKA (703 Slovakia, belonging to the institution)

Edition

Amsterdam, Procedia Earth and Planetary Science, vol. 15 : The World Multidisciplinary Earth Sciences Symposium, WMESS 2015, p. 304-308, 5 pp. 2015

Publisher

Elsevier

Other information

Language

English

Type of outcome

Stať ve sborníku

Field of Study

20101 Civil engineering

Country of publisher

Netherlands

Confidentiality degree

není předmětem státního či obchodního tajemství

Publication form

electronic version available online

RIV identification code

RIV/75081431:_____/15:00000601

Organization unit

Institute of Technology and Business in České Budějovice

ISSN

UT WoS

000370751200047

Keywords (in Czech)

polyesterová vlákna; zlepšení půdy; rozptýlená výztuž; krabicová smyková zkouška; úhel vnitřního tření; soudržnost.

Keywords in English

polyester fibres; soil improvement; random reinforcement; direct shear test; angle of internal friction; cohesion.

Tags

Tags

Reviewed
Změněno: 18/4/2016 08:34, Věra Kostková

Abstract

V originále

The paper deals with sensibility of sandy soils shear strength parameters on the size of spread foundation. Minimal, intermediate and maximal values of shear strength parameters of 5 classes of sandy soil (SW, SP, S-F, SM and SC) introduced in the old Slovak Technical Standard STN 731001 had been used to design model spread foundation, similar with this one, posted by Orr (2005). The foundation has square shape, thickness 0.8m, founded in the depth D = 1.5m. The foundation is loaded by centrically acting vertical permanent load G = 900 kN and variable load Q = 600 kN. Underground water level is at foundation base. The spread foundation was designed by design approaches mentioned in Eurocode 7, Part 1 (DA1-C1; DA1-C2; DA2 and DA3) and also by the old and new Slovak Technical Standard STN 73 1001.

In Czech

Článek pojednává o citlivosti parametrů smykové pevnosti písčitých základových půd při návrhu velikosti plošného základu. Minimální, střední a maximální hodnoty smykové pevnosti parametrů 5 tříd písčité půdy (SW, SP, SF, SM a SC), zavedené v původní normě STN 73 1001 byla použita k návrhu modelu plošného základu, podobného jaký přezentoval, Orr (2005). Základ byl čtvercového tvaru, tloušťky 0,8 m, založen byl v hloubce D = 1,5 m. Základ při zatížení svislou centrickou silou od stálého zatížení hodnotou G = 900 kN a proměnlivého zatížení Q = 600 kN. Hladina podzemní vody byla v základové spáře. Základ byl navržen dle návrhového přístupu uvedeného v Eurokódu 7, část 1 (DA1-C1, DA1-C2, DA2 a DA3), a také dle staré a nové Slovenské technické normy STN 73 1001.