Detailed Information on Publication Record
2015
Sensibility of Sandy Soils Shear Strength Parameters on a Size of Spread Foundation
NGUYEN, Giang, Terezie VONDRÁČKOVÁ, Marian DRUSA, Luboš KOVALČÍK, Ondrej STOPKA et. al.Basic information
Original name
Sensibility of Sandy Soils Shear Strength Parameters on a Size of Spread Foundation
Name in Czech
Citlivost smykových parametrů písčitých základových půd na velikost plošného základu
Authors
NGUYEN, Giang (704 Viet Nam), Terezie VONDRÁČKOVÁ (203 Czech Republic, belonging to the institution), Marian DRUSA (703 Slovakia), Luboš KOVALČÍK (703 Slovakia) and Ondrej STOPKA (703 Slovakia, belonging to the institution)
Edition
Amsterdam, Procedia Earth and Planetary Science, vol. 15 : The World Multidisciplinary Earth Sciences Symposium, WMESS 2015, p. 304-308, 5 pp. 2015
Publisher
Elsevier
Other information
Language
English
Type of outcome
Stať ve sborníku
Field of Study
20101 Civil engineering
Country of publisher
Netherlands
Confidentiality degree
není předmětem státního či obchodního tajemství
Publication form
electronic version available online
RIV identification code
RIV/75081431:_____/15:00000601
Organization unit
Institute of Technology and Business in České Budějovice
ISSN
UT WoS
000370751200047
Keywords (in Czech)
polyesterová vlákna; zlepšení půdy; rozptýlená výztuž; krabicová smyková zkouška; úhel vnitřního tření; soudržnost.
Keywords in English
polyester fibres; soil improvement; random reinforcement; direct shear test; angle of internal friction; cohesion.
Tags
Reviewed
Změněno: 18/4/2016 08:34, Věra Kostková
V originále
The paper deals with sensibility of sandy soils shear strength parameters on the size of spread foundation. Minimal, intermediate and maximal values of shear strength parameters of 5 classes of sandy soil (SW, SP, S-F, SM and SC) introduced in the old Slovak Technical Standard STN 731001 had been used to design model spread foundation, similar with this one, posted by Orr (2005). The foundation has square shape, thickness 0.8m, founded in the depth D = 1.5m. The foundation is loaded by centrically acting vertical permanent load G = 900 kN and variable load Q = 600 kN. Underground water level is at foundation base. The spread foundation was designed by design approaches mentioned in Eurocode 7, Part 1 (DA1-C1; DA1-C2; DA2 and DA3) and also by the old and new Slovak Technical Standard STN 73 1001.
In Czech
Článek pojednává o citlivosti parametrů smykové pevnosti písčitých základových půd při návrhu velikosti plošného základu. Minimální, střední a maximální hodnoty smykové pevnosti parametrů 5 tříd písčité půdy (SW, SP, SF, SM a SC), zavedené v původní normě STN 73 1001 byla použita k návrhu modelu plošného základu, podobného jaký přezentoval, Orr (2005). Základ byl čtvercového tvaru, tloušťky 0,8 m, založen byl v hloubce D = 1,5 m. Základ při zatížení svislou centrickou silou od stálého zatížení hodnotou G = 900 kN a proměnlivého zatížení Q = 600 kN. Hladina podzemní vody byla v základové spáře. Základ byl navržen dle návrhového přístupu uvedeného v Eurokódu 7, část 1 (DA1-C1, DA1-C2, DA2 a DA3), a také dle staré a nové Slovenské technické normy STN 73 1001.